Rohl Perrin & Rowe GEORGIAN ERA U.KIT1307 Скачать руководство пользователя страница 4

INSTALLATION INSTRUCTIONS

Preparation for the installation.

Flush the pipework before

installing this tapware.

Once unpacked, remove nuts and clamping
plate ready for installation

IMPORTANT INFORMATION

Before you proceed... We recommend you engage the services of a registered plumber to install this

product.

Perrin & Rowe taps require a maximum inlet pressure supply of 75psi. For installations where the
inlet water supply pressure is ever above 75psi, pressure-limiting valves must be installed prior to
this tap.

It is essential that the information contained herein is carefully read and understood prior to
installing and operating this tap.

Congratulations on the purchase of your Perrin and Rowe Kitchen Product. Correctly installed

and with sensible care, this product will give you many years of trouble free service.

The Mini Hot Dispensers Collection
Installation & User Guide

THREADED STUD

CLAMPING PLATE

NUT

BASE SEAL

WORK

SURFACE

NYLOCK NUT

BOX 

SPANNER

(PROVIDED)

1 3

/4"

 MAX

1

Mounting dispenser:

• Feed the flexible connections
through the ø1

1/4

" work surface hole

ensuring the base seal is in place

between tap and mounting surface.

• Ensure the base ring and tap are

orientated correctly, Hot water lever
should rotate to point forwards. The
spout fixing screw should be at the

back.

• Secure by using the clamping plate

and nuts. (box spanner is provided)

Attach the flow regulator

9/16

" to the

Cold inlet and then connect the

9/16

"

flexible hose end to the flow
regulator.

Ensure all connections are firmly
tightened.

Consult the guide provided with the

heater tank to ensure correct

positioning and installation.

BASE RING

ENSURE THE SILICONE TUBE

PROTECTOR IS IN PLACE,

CENTRAL AGAINST THE BASE

OF THE TAP.

9/16" 

COLD IN

3

Silicone Hose

Trim the silicone hose to the right length for the installation. It must not be pulled taught, too
slack leading to a 'U' bend or twisted. Please make sure the tube isn't pinched between the

threaded stud and the braided hose as this may cause flow restriction. If the silicone is not
installed correctly it may effect the performance of the system.

4

Operation

For instant hot water,

press down on the

lever/button and rotate

handle forward.

Once finished, release the

handle and the valve will

automatically close.

2

G3/8"

FEED TO

HEATER TANK

THROUGH FILTER

SILICONE TUBE

HOT FEED BACK

TO THE TAP

Connections to the filter (U.1106) and heater tank U.1998:
(See separate filter guide and heater tank installation for

further installation instructions)

• Mount the filter housing in an accessible location using

either screws in the bracket or the adhesive pad, ensuring the
mounting area is clean by using the wipe provided.

• Once the mains connections are made fit the G3/8" braided

hose to the filter as shown.

• Connect the silicone tube to the barbed connection on the

top of the heater tank as shown. (SEE NOTE 3 BELOW)

IMPORTANT: During installation the tank should remain

unplugged. The tank must be filled with water before power is

connected. A 'dry start' will void the warranty.

Avoid kinking tubes during installation as the resulting
restrictions could reduce flow and cause malfunctioning of
the expansion chamber. Do not use pipe sealing compounds on
any connections. These can foul the internal mechanics and

may cause objectionable taste and odor. Plumbing connections

must comply with all sanitary, safety and plumbing codes.

AVOID TRAPPING

SILICONE HOSE

BETWEEN STUD &

BRAIDED HOSES

SILICONE 

TUBE 

RETAINER 

CLIP

FLOW REGULATOR

9/16" FEMALE - MALE

9/16" FLEXI-HOSE

FLOW REGULATOR

O

3/8" COMPRESSION SERVICE VALVE

O

3/8" COMPRESSION 

SERVICE VALVE

houseofrohl.com

Consult your local House of Rohl showroom for additional information and specifications. For complete warranty details and a list of showrooms, go to houseofrohl.com

Содержание Perrin & Rowe GEORGIAN ERA U.KIT1307

Страница 1: ...ridge PERRIN ROWE GEORGIAN ERA C SPOUT HOT WATER FAUCET TANK AND FILTER KIT U KIT1307 Ø1 1 4 HOLE 6 1 2 5 1 2 1 3 4 MAX Ø1 7 8 10 3 3 4 2 3 8 12 1 2 9 8 TO HOT TANK INLET FROM FAUCET Ø2 PLEASE ALLOW 12 1 2 MINIMUM TO ALLOW FOR FILTER REPLACEMENT 11 3 4 7 1 2 Ø1 3 4 5 year Limited Warranty on Faucet 3 year Limited Warranty on Tank No Warranty Polished Chrome Polished Nickel Satin Nickel English Bro...

Страница 2: ...S TO MINIMISE RISK AND POTENTIAL INJURY TWO ACTION OPERATION SPRING BACK VALVE AND DELAYED DELIVERY BUT SHOULD BE OPERATED OR SUPERVISED BY A RESPONSIBLE ADULT PLEASE READ AND FULLY UNDERSTAND THE HEATER TANK INSTRUCTIONS BEFORE USE Registration Please visit www rohlhome com filtration registration aspx complete the registration card postage paid or phone 1 800 777 9762 to register your product O1...

Страница 3: ...ser Feed the flexible connections through the ø1 1 4 work surface hole ensuring the base seal is in place between tap and mounting surface Ensure the base ring and tap are orientated correctly Hot water lever should rotate to point forwards The spout fixing screw should be at the back Secure by using the clamping plate and nuts box spanner is provided Attach the flow regulator 9 16 to the Cold inl...

Страница 4: ...1106 and heater tank U 1998 See separate filter guide and heater tank installation for further installation instructions Mount the filter housing in an accessible location using either screws in the bracket or the adhesive pad ensuring the mounting area is clean by using the wipe provided Once the mains connections are made fit the G3 8 braided hose to the filter as shown Connect the silicone tube...

Страница 5: ...age the plated finish and void your warranty BEFORE USE Carefully check the installation for leaks If further building work is to be carried out in the vicinity cover the mixer tap to avoid damaging the finish Please ensure that the installation complies with the local plumbing codes NOTE Diagram shows set up with u 1998 he tank and u 1106 filte ROHL WARRANTY POLICY All products supplied by ROHL c...

Страница 6: ...Please read these instructions fully before commencing the installation and operation of the Electronic Instant Hot Water Appliance houseofrohl com Consult your local House of Rohl showroom for additional information and specifications For complete warranty details and a list of showrooms go to houseofrohl com ...

Страница 7: ...uld only be installed by a competent person if you feel for any reason unsure about the installation please contact a qualified plumber or electrician to install the appliance Make sure all electrical wiring and connections conform to local standards Make sure all water connections conform to local standards Make sure all electrical wiring and water connections conform to local codes Standard 120v...

Страница 8: ...Shock Using an ungrounded connection or improper connection of the power sup ply to the product can result in a serious injury or death from electrical shock Electric Shock Do not remove the earthing terminal Do not reconstruct the plug Do not disassemble main box and any part for the power Important The instructions are only intended as a guide if there is any doubt then please contact a certifie...

Страница 9: ...ure the front of the unit is visible and the front temperature dial can be easily reached Do not attempt to open modify or service this electronic instant hot water appliance Re pairs should be carried out by Authorised Service personnel Opening the unit will void the guarantee The required water supply pressure is a minimum of 22psi to maximum of 72psi Turn off all controls before unplugging Do n...

Страница 10: ...wise the pipes and the Dispenser and tank will be frozen and there will be serious safety trouble possible bodily injury acci dents and damaged caused and the guarantee will be void It s forbidden to wash the electronic instant hot water appliance with water directly The installation environment should be ventilated with protection from the direct sun shine When installing the electronic instant h...

Страница 11: ...nic instant hot water appliance is not under pressure consequently there is a slight delay in water flow after the hot water springback Dispenser handle has been turned on This is normal and indicates that the electronic instant hot water appliance is function ing properly It is recommended that you have access to a separate power circuit serving only your elec tronic instant hot water appliance S...

Страница 12: ... socket it must be tested for water tightness and no leaks Open all water valves to allow water to flow to the instant hot water Dispenser Turn the spring back instant hot water handle and hold to fill the electronic instant hot water appliance this will take about 90 seconds When the electronic instant hot water appliance is full water will flow from the instant hot water Dispenser spout Initiall...

Страница 13: ...gs 208 F max 206 F 203 F 194 F 185 F 176 F 167 F To turn on the electronic instant hot water appliance touch the button and hold for 3 seconds until the display lights up Touch the button and press each time so that the temperature settings will change from 167 F to 176 F to 194 F to 185 F to 194 F to 203 F to 206 F to 208 F continue to press till the required temperature is seen To confirm the te...

Страница 14: ...low the tank to cool for at least 1 hour Disconnect the inlet supply to the tank and remove the silicone hose out let pipe lift the unit to the sink turn upside down and drain all the water from the tank When re installing follow the original installation instructions The electronic instant hot water appliance like any water heater has a limited operational life span and will eventually fail In or...

Страница 15: ...the circuit breaker and fuse are working correctly Turn on the power and touch the on off button and then set the required temperature and confirm the heat up Water is too hot Water temperature setting on display panel is set to high Re set the temperature to the required temperature and con firm the heating up Water is dripping from the instant hot water Dispenser spout The expansion chamber isn ...

Страница 16: ...olume of water has been drawn off there may a slightly longer delay in the wa ter appearing from the instant hot water Dispenser spout Check length of silicon pipe No Water Flowing Water Valves have been turned off Inlet Pipes have been twisted or blocked Turn on all the water valves Ensure the pipes are not twisted or kinked to restrict flow Remove and clean the aerator IF YOU ARE IN ANY DOUBT TH...

Страница 17: ...lhome com Guarantee Void Unless The Water Filter Is Replaced Every 6 Months Issue PRV114112017 Rohl Perrin Rowe are Registered trade marks houseofrohl com Consult your local House of Rohl showroom for additional information and specifications For complete warranty details and a list of showrooms go to houseofrohl com ...

Страница 18: ...ady to use it is vitally important that you follow the process below to ensure that all air is bled from the system P Pl la ac ce e a a j ju ug g u un nd de er r t th he e s sp po ou ut t a as s w wa at te er r w wi il ll l s sp pl lu ut tt te er r f fr ro om m t th he e s sp po ou ut t u un nt ti il l a al ll l o of f t th he e a ai ir r i is s e ex xp pe el ll le ed d Operate the instant hot tap...

Страница 19: ... th ho or ro ou ug gh hl ly y c ch he ec ck k t th he e u un ni it t f fo or r a an ny y w wa at te er r l le ea ak ks s b be ef fo or re e y yo ou u c co on nt ti in nu ue e 2 G3 8 BRAIDED HOSE FROM TAP PUSH FIT BRAIDED HOSE TO HEATER TANK DIRECTION OF FLOW Fixing Mounting Bracket Attaching Hoses FILTER SUMP 9 16 DOMESTIC HOT IN 9 16 COLD IN 3 System Layout DIRECTION OF FLOW G3 8 BRAIDED HOSE FRO...

Отзывы: