Figure 6-4: Cage nuts for metric M5 screws (not included in the delivery)
Start with the chamber unpacked and transported to the operating site, but not yet
positioned and mounted on a support.
To mount the chamber in a rack
For mounting the chamber into a rack, proceed as follows:
1. Prepare the rack with stable rails that jointly can carry a load of at least 45.
2. Mount the rails at the desired altitude, as described the rack manufacturer's mount-
ing instructions.
Make sure that from the level of the rails, a height of 10
HU (444.5
mm) is available
for the chamber.
3.
WARNING!
Door of the chamber is heavy and can move. If the door slides open
while you lift the chamber, the center of gravity shifts. The door hitting its end posi-
tion results in a powerful thrust.
If the door is not secured against opening by the metal safety latch (
),
secure it as described in
4.
WARNING!
Risk of injury due to heavy weight. See
Chapter 5.1, "Lifting and Carry-
With at least 2 people lifting, insert the chamber into the rack.
5. Position the chamber in the rack in such a way that the front of the chamber's body
(not the front of the door) is flush with the front of the rack.
6. Remove the metal safety latch.
Keep the safety latch for future transportation of the chamber.
7. Take the included set of screws:
Mounting the Chamber