Remote control commands
R&S
®
SMM100A
855
User Manual 1179.1341.02 ─ 05
[:SOURce<hw>]:BB:MCCW:TRIGger:RMODe?
Queries the status of signal generation for all trigger mode, if multi-carrier CW genera-
tion is on.
Return values:
<RMode>
STOP | RUN
Example:
See
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:BB:MCCW:TRIGger:SLENgth
<SLength>
Defines the length of the signal sequence to be output in the "Single" trigger mode.
Parameters:
<SLength>
integer
Range:
1 to 1000
*RST:
1
Default unit: samples
Example:
See
Manual operation:
See
[:SOURce<hw>]:BB:MCCW:TRIGger:SOURce
<Source>
Selects the trigger signal source and determines the way the triggering is executed.
Provided are:
●
Internal triggering by a command (
INTernal
)
●
External trigger signal via one of the local or global connectors
–
EGT1|EGT2
: External global trigger
–
EGC1|EGC2
: External global clock
●
In primary-secondary instrument mode, the external baseband synchronization sig-
nal (
BBSY
)
●
OBASeband|BEXTernal|EXTernal
: Setting only
Provided only for backward compatibility with other Rohde
&
Schwarz signal gener-
ators.
The R&S
SMM100A accepts these values and maps them automatically as follows:
EXTernal = EGT1
,
BEXTernal = EGT2
,
OBASeband = INTA
Parameters:
<Source>
INTernal|EGT1|EGT2|EGC1|EGC2|EXTernal|BBSY
*RST:
INTernal
Example:
See
Manual operation:
See
SOURce subsystem