Functions
R&S
®
OSP
171
User Manual 1178.7100.02 ─ 05
A = SPDT relay, top icon in deactivated state, lower icon activated
B = DPDT relay, top icon in deactivated state, lower icon activated
C = SP6T relay, terminal position 6 is activated
D = SP8T relay, terminal position 4 is activated
E = Output channel, top icon in deactivated state, lower icon activated
Generally, items marked in blue color in the user interface are active.
To deactivate an active item, tap or click it again.
If there are multi-pole relays, you can click or tap the "open switch" button to open any
previously closed connection:
Figure 5-17: The "open switch" button resets a multi-pole relay to its default open state
Figure 5-18: Dialog for switching relays and output channels
Red circles = Switched relays (K11, K12) and switched channels (CH2, CH3)
The switched relays and channels in
are in a state that is different from
their deactivated state. In contrast with these bistable components, there are multista-
Module Operation