General Description
R&S
®
CMW-KM750/-KM751
27
User Manual 1173.9670.02 ─ 05
●
Code Domain Power (CDP)
●
Code Domain Error (CDE)
●
Power vs. Time
Each of the detailed views shows one or two diagrams and a statistical overview of single-
slot results (except Code Domain Monitor).
Fig. 3-14: TD-SCDMA Multi Evaluation: Magnitude Error
●
Error Vector Magnitude, Magnitude Error, and Phase Error
The diagrams labeled "Preselected Slot" cover up to 848 chips of this slot (all 864
chips of the slot excluding the 16 chip guard period at the end) and contain one mea-
surement result per chip.
The diagrams labeled "Multi Slot" cover up to 112 timeslots and contain one mea-
surement result per slot.
●
Code Domain Monitor
The diagrams display the Code Domain Power (CDP) and Code Domain Error (CDE)
for all code channels, measured in the "Preselected Slot". The results are determined
assuming a selectable uniform spreading factor (SF) for all channels. The number of
displayed bars (code channels) corresponds to the selected SF. A signal component
with a spreading factor smaller than the selected SF occupies several adjacent bars.
●
Code Domain Power (CDP), Code Domain Error (CDE)
The diagrams labeled "Preselected Slot" display the CDP and CDE for all physical
channels (DPCHs and SICH), measured in this slot. Each diagram contains 16 bars,
corresponding to up to 16 channels. Channels with a spreading factor smaller than
Measurement Results