Rohde & Schwarz CMU-Z6 Скачать руководство пользователя страница 3

 

1171.0000.42-02.00  

Sheet 

Before putting the product into operation for 

the first time, make sure to read the following

 

 

S a f e t y   I n s t r u c t i o n s  

 

 

Rohde & Schwarz makes every effort to keep the safety standard of its products up to date and to offer 
its customers the highest possible degree of safety. Our products and the auxiliary equipment required 
for them are designed and tested in accordance with the relevant safety standards. Compliance with 
these standards is continuously monitored by our quality assurance system. This product has been 
designed and tested in accordance with the EC Certificate of Conformity and has left the manufacturer’s 
plant in a condition fully complying with safety standards. To maintain this condition and to ensure safe 
operation, observe all instructions and warnings provided in this manual. If you have any questions 
regarding these safety instructions, Rohde & Schwarz will be happy to answer them. 

Furthermore, it is your responsibility to use the product in an appropriate manner. This product is 
designed for use solely in industrial and laboratory environments or in the field and must not be used in 
any way that may cause personal injury or property damage. You are responsible if the product is used 
for an intention other than its designated purpose or in disregard of the manufacturer's instructions. The 
manufacturer shall assume no responsibility for such use of the product.  

The product is used for its designated purpose if it is used in accordance with its operating manual and 
within its performance limits (see data sheet, documentation, the following safety instructions). Using 
the products requires technical skills and knowledge of English. It is therefore essential that the 
products be used exclusively by skilled and specialized staff or thoroughly trained personnel with the 
required skills. If personal safety gear is required for using Rohde & Schwarz products, this will be 
indicated at the appropriate place in the product documentation.  

Symbols and safety labels

 

 

 

 

 

 

 

 

 

Observe 
operating 
instructions 

Weight 
indication for 
units >18 kg 

Danger of 
electric 
shock 

Warning! 
Hot 
surface 

PE terminal 

Ground 

Ground 
terminal 

Attention! 
Electrostatic 
sensitive 
devices 

 

   

 

 

 

 

 

 

Supply 
voltage 
ON/OFF 

Standby 
indication 

Direct 
current 
(DC) 

Alternating 
current (AC) 

Direct/alternating 
current (DC/AC) 

Device fully 
protected by 
double/reinforced 
insulation 

Содержание CMU-Z6

Страница 1: ...1150 0199 12 03 1 Test and Measurement Division Operating Instructions Improvement of Wideband Modulation Analysis CMU Z6 1150 0001 02 Printed in the Federal Republic of Germany...

Страница 2: ......

Страница 3: ...ory environments or in the field and must not be used in any way that may cause personal injury or property damage You are responsible if the product is used for an intention other than its designated...

Страница 4: ...r unassociated documentation can result in misinterpretations and thus contribute to personal injury or material damage Basic safety instructions 1 The product may be operated only under the operating...

Страница 5: ...ccordingly 9 In the case of products of safety class I with movable power cord and connector operation is permitted only on sockets with earthing contact and protective earth connection 10 Intentional...

Страница 6: ...roperly replaced this can cause an explosion warning lithium cells Replace the battery or storage battery only with the matching Rohde Schwarz type see spare parts list Batteries and storage batteries...

Страница 7: ...a persona cosa pueda ser da ada El uso del producto fuera de sus fines definidos o despreciando las informaciones de seguridad del fabricante queda en la responsabilidad del usuario El fabricante no s...

Страница 8: ...definici n Por eso se debera tener en cuenta que las palabras de se al aqu descritas sean utilizadas siempre solamente en combinaci n con la correspondiente documentaci n y solamente en combinaci n co...

Страница 9: ...da En vista a la protecci n de la vida en desarrollo deber an ser protegidas personas embarazadas debidamente Tambi n las personas con un bypass pueden correr peligro a causa de la radiaci n electroma...

Страница 10: ...y la conexi n deber n ser efecutadas por un electricista especializado 20 En caso de que los productos que son instalados fijamente en un lugar sean sin protector implementado autointerruptor o simila...

Страница 11: ...ejemplo paredes y estantes 31 Las asas instaladas en los productos sirven solamente de ayuda para el manejo que solamente est previsto para personas Por eso no est permitido utilizar las asas para la...

Страница 12: ......

Страница 13: ...mode REF IN RF OUT DC Supply Rohde Schwarz CMU Z6 1150 0001 02 0 1 A 1 0 B 1 1 C MODE SETTING ON Input for 110 8 MHz reference frequency DC power supply Output for test signal LEDs indicating the ope...

Страница 14: ...with the 5 V DC power from the AUX connector at the rear panel of the CMU Use the two N to BNC cables to provide CMU Z6 with a 110 8 MHz reference frequency from RF3 OUT and to feed the generated test...

Страница 15: ...ormal operating temperature of the CMU otherwise the correction values might be impaired Checking the Corrected Measurement The accuracy of the corrected modulation measurement can be checked by using...

Страница 16: ...on measurement Perform a Preset of the SMIQ settings and a Reset of the CMU Set the SMIQ to comply with the CMU default analyzer settings FREQUENCY 1922 4 MHz LEVEL 0 dBm DIGITAL MOD STATE ON SELECT S...

Отзывы: