Installation and Operation
Choosing the Operating Site
CLIPSTER
34
User Manual (Hardware) | 2904.4460.02 - 04
Choosing the Operating Site
Specific operating conditions ensure proper operation and avoid damage to
the product and connected devices. For information on environmental condi-
tions such as ambient temperature and humidity, see the data sheet.
See also "Choosing the Operating Site" on page 9.
Electromagnetic compatibility classes
The electromagnetic compatibility (EMC) class indicates where you can
operate the product. The EMC class of the product is given in the data sheet
under "General data".
●
Class B equipment is suitable for use in:
- Residential environments
- Environments that are directly connected to a low-voltage supply
network that supplies residential buildings
●
Class A equipment is intended for use in industrial environments. It can
cause radio disturbances in residential environments due to possible
conducted and radiated disturbances. It is therefore not suitable for class
B environments.
If class A equipment causes radio disturbances, take appropriate measures
to eliminate them.
Mounting the System into a Rack
The system is to be operated in a 19-inch wide rack.
Rack System Precautions
The following safety requirements must be considered when the unit is
mounted in a rack.
●
The rack construction must be capable of supporting the total weight of
the installed enclosure(s) and the design should incorporate stabilizing
features suitable to prevent the rack from tipping or being pushed over
during installation or in normal use.
●
The system must be operated with low pressure rear exhaust installation
[back pressure created by rack doors and obstacles not to exceed 5
pascals (0.5mm water gauge)].
●
The rack design should take into consideration the maximum operating
ambient temperature for the unit, which is 35°C.
●
The rack should have a safe electrical distribution system. It must
provide over-current protection for the unit and must not be overloaded
by the total number of units installed in the rack. When addressing these
concerns consideration should be given to the electrical power consump-
tion rating shown on the nameplate.
●
The electrical distribution system must provide a reliable earth for each
unit in the rack.