GUI Reference
R&S
®
ZNA
285
User Manual 1178.6462.02 ─ 12
Trace mode
Infinite averaging
Hold mode
"Clear Write"
OFF
"Hold OFF"
"AVG"
ON
"Hold OFF"
"Min Hold"
OFF
"Min Hold"
"Max Hold"
OFF
"Max Hold"
Use
to reset the averaging/minimization/maximization history.
Remote command:
Use the commands for
according to the table above.
Reset History
Resets the trace calculation history for
"AVG", "Min Hold", and "Max Hold".
Remote command:
"AVG":
CALCulate<Chn>:IAVerage[:STATe]
OFF; IAVerage ON
"Min Hold":
OFF; PHOLd MIN
"Min Hold":
OFF; PHOLd MAX
Detector
The "Detector" defines how the measurement result for a particular sweep point is
derived from the related sample values.
Maximum
Peak
Determines the largest of all levels measured at the individual fre-
quencies which are displayed in one sample point.
Minimum Peak Determines the smallest of all levels measured at the individual fre-
quencies which are displayed in one sample point.
RMS
Calculates the root mean square of all samples contained in a sweep
point.
Average
Calculates the arithmetic mean of all samples contained in a sweep
point.
Remote command:
Port Settings...
.
6.2.11.2
Spectrum Setup Dialog
Allows you to set up channels for the spectrum measurement. For spectrum measure-
ments on frequency-converting DUTs, the "Spectrum Setup" dialog also comprises the
mixer configuration.
Meas Softtool