R&S FSH
Cable Measurements
1145.5973.12 4.111
E-11
Press the ENTER key or the LIST VIEW softkey
again.
The R&S FSH displays a table listing all the reflections
that are above the threshold sorted according to
distance from the measurement plane.
To change the threshold for the table display,
press the THRESHOLD softkey and enter the new
value.
Use LIST->PRINTER to output the list to a printer.
To close the list and to return to the graphics
display mode, press the EXIT softkey.
Locating cable faults by means of the marker function
The distance to cable faults or the distance between any two faults can also be read off with the marker.
Press the MARKER key.
The R&S FSH opens the marker menu and places the
marker on the fault with the largest reflection. The
marker readout gives the distance of the fault from the
measurement plane in meters and its return loss.
The marker that indicates the distance from the
measurement plane is renamed the DISTANCE
MARKER. It is activated for entry (DISTANCE value
entry box).
Change the distance marker by entering a number,
adjusting the rotary knob (pixel by pixel) or by
using the cursor keys (step = 10 % of the span).