Rogers Smart Home Monitoring Скачать руководство пользователя страница 5

5

Smart Home Monitoring  |  In-Wall Switch or In-Wall Dimmer  |  Manufacturer's Installation Guide

The Jasco Auxiliary switch is required for Multi-Switch 3-way or 4-way installations. 

Connecting the traveler terminal of this switch to a standard, non-Jasco switch will cause 
damage or result in improper function. If this switch is a part of a 3-way or 4-way multi-
switch installation, do not connect the traveler wire or apply power until Jasco Auxiliary 
switches are correctly installed. For more information on 3-way or 4-way installations, view 
the manual or quick-start guide that comes with the Jasco Auxiliary switch.

7.  Connect the green or bare copper ground wire 

to the GROUND terminal.

8.  Connect the black wire that goes to the light to 

the terminal marked LOAD.

9.  Connect the black wire that comes from the 

electrical service panel (Hot) to the terminal 
marked LINE.

10.  Connect the white wire to the neutral terminal.

Note:

 UL specifies that the tightening torque for the 

screws is 14 Kgf-cm (12 lbf-in). The Traveler terminal is 
only used for 3-way or 4-way wiring and should 
remain insulated if the switch is being installed in a 
2-way system (one switch & one load).

11.  Insert Switch into the switch box being careful 

not to pinch or crush wires.

12.  Secure the switch to the box using the supplied 

screws.

13.  Mount the wall plate.

14.  Reapply power to the circuit at fuse box or circuit 

breaker and test the system.

Содержание Smart Home Monitoring

Страница 1: ...In Wall Switch or In Wall Dimmer Manufacturer s Installation Guide ...

Страница 2: ...way control three switches one load When used by itself for 2 way control please make sure that the screw terminal for the traveler wire is insulated Do not remove the tape over the terminal if you are not using the traveler connection This dimmer switch is designed for use with permanently installed lighting fixtures only The switch has been optimized for use with incandescent lighting as well as...

Страница 3: ...3 Smart Home Monitoring In Wall Switch or In Wall Dimmer Manufacturer s Installation Guide Wiring Diagrams ...

Страница 4: ...o switch box before continuing 2 Remove wall plate 3 Remove the existing switch s mounting screws 4 Carefully remove the existing switch from the switch box DO NOT disconnect the wires 5 There are up to five screw terminals on the existing switch these are marked A LINE Hot Black connected to power B Neutral White C LOAD Black connected to lightning D GROUND Green Bare E TRAVELER Red Other Match t...

Страница 5: ...iliary switch 7 Connect the green or bare copper ground wire to the GROUND terminal 8 Connect the black wire that goes to the light to the terminal marked LOAD 9 Connect the black wire that comes from the electrical service panel Hot to the terminal marked LINE 10 Connect the white wire to the neutral terminal Note UL specifies that the tightening torque for the screws is 14 Kgf cm 12 lbf in The T...

Отзывы: