background image

4

Smart Home Monitoring  |  In-Wall Switch or In-Wall Dimmer  |  Manufacturer's Installation Guide

Single, Dual and Triple Gang Boxes

When installing the In-Wall On/Off switch in multiple 
gang boxes it may be necessary to break off one or 
both of the scored tabs on the front yoke.

Wiring Instructions

1.  Shut off power to the circuit at circuit breaker or 

fuse box.

Warning:

 Verify power is OFF to switch box before 

continuing.

2.  Remove wall plate.

3.  Remove the existing switch's mounting screws.

4.  Carefully remove the existing switch from the 

switch box. DO NOT disconnect the wires.

5.  There are up to five screw terminals on the 

existing switch; these are marked  
A. LINE (Hot) — Black (connected to power)  
B. Neutral — White  
C. LOAD — Black (connected to lightning)  
D. GROUND — Green/Bare  
E. TRAVELER — Red/Other

Match these screw terminals to the wires connected 
to the existing switch.

6.  Disconnect the wires from the existing switch.  

Be careful to label wires according to the 
previous terminal connection.

Содержание Smart Home Monitoring

Страница 1: ...In Wall Switch or In Wall Dimmer Manufacturer s Installation Guide ...

Страница 2: ...way control three switches one load When used by itself for 2 way control please make sure that the screw terminal for the traveler wire is insulated Do not remove the tape over the terminal if you are not using the traveler connection This dimmer switch is designed for use with permanently installed lighting fixtures only The switch has been optimized for use with incandescent lighting as well as...

Страница 3: ...3 Smart Home Monitoring In Wall Switch or In Wall Dimmer Manufacturer s Installation Guide Wiring Diagrams ...

Страница 4: ...o switch box before continuing 2 Remove wall plate 3 Remove the existing switch s mounting screws 4 Carefully remove the existing switch from the switch box DO NOT disconnect the wires 5 There are up to five screw terminals on the existing switch these are marked A LINE Hot Black connected to power B Neutral White C LOAD Black connected to lightning D GROUND Green Bare E TRAVELER Red Other Match t...

Страница 5: ...iliary switch 7 Connect the green or bare copper ground wire to the GROUND terminal 8 Connect the black wire that goes to the light to the terminal marked LOAD 9 Connect the black wire that comes from the electrical service panel Hot to the terminal marked LINE 10 Connect the white wire to the neutral terminal Note UL specifies that the tightening torque for the screws is 14 Kgf cm 12 lbf in The T...

Отзывы: