Rogers Smart Home Monitoring Скачать руководство пользователя страница 2

2

Smart Home Monitoring  |  In-Wall Switch or In-Wall Dimmer  |  Manufacturer's Installation Guide

Installation Configurations

This switch may be used in new installations or to replace an existing wall switch.

It may be used in the following configurations:

 

By itself for 2-way control (one switch & one load)

 

By adding one Jasco Auxiliary Switch for 3-way control (two switches & one load)

 

By add two Jasco Auxiliary switches for 4-way control (three switches & one load)

When used by itself for 2-way control, please make sure that the screw terminal for the 
traveler wire is insulated. Do not remove the tape over the terminal if you are not using  
the traveler connection.

This dimmer switch is designed for use with permanently installed lighting fixtures only. 
The switch has been optimized for use with incandescent lighting as well as with most 
dimmable CFL and LED bulbs. The maximum load ratings for this switch are 600W for 
incandescent bulbs and 150W for dimmable CFL and LED’s. Lighting controlled by this 
switch must not exceed these stated limits.

Содержание Smart Home Monitoring

Страница 1: ...In Wall Switch or In Wall Dimmer Manufacturer s Installation Guide ...

Страница 2: ...way control three switches one load When used by itself for 2 way control please make sure that the screw terminal for the traveler wire is insulated Do not remove the tape over the terminal if you are not using the traveler connection This dimmer switch is designed for use with permanently installed lighting fixtures only The switch has been optimized for use with incandescent lighting as well as...

Страница 3: ...3 Smart Home Monitoring In Wall Switch or In Wall Dimmer Manufacturer s Installation Guide Wiring Diagrams ...

Страница 4: ...o switch box before continuing 2 Remove wall plate 3 Remove the existing switch s mounting screws 4 Carefully remove the existing switch from the switch box DO NOT disconnect the wires 5 There are up to five screw terminals on the existing switch these are marked A LINE Hot Black connected to power B Neutral White C LOAD Black connected to lightning D GROUND Green Bare E TRAVELER Red Other Match t...

Страница 5: ...iliary switch 7 Connect the green or bare copper ground wire to the GROUND terminal 8 Connect the black wire that goes to the light to the terminal marked LOAD 9 Connect the black wire that comes from the electrical service panel Hot to the terminal marked LINE 10 Connect the white wire to the neutral terminal Note UL specifies that the tightening torque for the screws is 14 Kgf cm 12 lbf in The T...

Отзывы: