Rogers PRT42 Скачать руководство пользователя страница 13

PRT42 and PRT42-BK v1.0 fv72 EN Rev.C 
 
 

 14 
 
 
 

6

 

S

T A N D

-

A L O N E  

O

P E R A T I O N

 

6.1

 

Users 

In the stand-alone mode, a PRT reader can register up to 120 users, each with a card, a 3 to 6 digit long PIN 
code and an ID number (000–119). The PRT reader precludes assignment of the same code or card to 2 
different users. Users enter their PIN codes keyed in with a press of the [#] key ([#] key is required to mark 
the end of PIN entry). User identification is done by verifying the PIN code entered or the card presented. When 
an option [Card+PIN] set users must present his card and subsequently enter its PIN. The [Card+PIN] option 
can be set separately for primary and secondary reader. 
 
The PRT reader supports five types (classes) of users: INSTALLER, MASTER, NORMAL, TOGGLE and TOGGLE 
LTD. The INSTALLER and MASTER Users are dedicated for programming purpose only. NORMAL Users are 
authorized to unlock the supervised door, but not to arming and disarming reader. TOGGLE Users are 
authorized both to unlock the system-supervised door and to switch reader between ARMED-DISARMED modes. 
TOGGLE LTD Users are authorized to change ARMED-DISARMED mode of the reader only, they are not 
authorized for door unlock. 
 
A new user can be registered in the device following either a simple or a full programming procedure. The 
simple procedure consists in programming a PIN code or a card into the system without specifying the ID 
number of a user to whom the programmed PIN/card will belong — so the system simply stores the code 
entered/card presented in a unoccupied ID user number. The full programming procedure requires you to 
specify an ID number for the new user being programmed which has to be followed by entering his PIN code 
and presenting his card. 

Note: When you program user using full programming procedure you will be able later to selectively delete a 
user simply by specifying his ID number, so you do not need to know his card or PIN code. 

User Types (User Classes) 

INSTALLER 

A card of this user allows you to enter Installer Programming Mode. INSTALLER 
user has no PIN code. 

MASTER 

A card of this user allows to enter User Programming Mode. MASTER user has no 
PIN code. 

NORMAL 

Users of this type are solely authorized to unlock the door. They can use a card 
or a PIN code. 

TOGGLE 

Users of this type have the authorization to unlock the door and to control the 
ARMED-DISARMED state of the reader. They can use a card or a PIN code. 

TOGGLE LTD 

Users of this type are solely authorized to control the ARMED-DISARMED state of 
the reader. They can use a card or a PIN code. 

6.2

 

ARMED and DISARMED Modes 

In the standalone mode, the reader can be in any of the operational states, either ARMED or DISARMED. Its 
current state is indicated by the reader’s dual color LED STATUS — it lights in RED for ARMED or GREEN for 
DISARMED. 
 
The change of the reader’s state to ARMED can be additionally indicated through the output line (for this, 
enable the Reader Disarmed Output setting). Such configuration allows the output line to be used as a driver to 
arm/disarm a connected alarm system or to switch on/off some other auxiliary system or device such as 
heating, lights etc. In general, the reader’s ARMED-DISARMED states has no effect on unlocking door, unless 
the Access Disabled When Reader Armed option has been enabled (see C13 digit in Installer Programming 
Mode). With this option activated, access to the supervised room is granted only when the reader is disarmed.  
Use of the reader’s configuration option mentioned above makes TOGGLE Users capable of enable/disable 
access to the supervised room; and it allows automatic access locking upon a reader entering the ARMED state. 

Note: Upon powering on, the reader automatically returns to the ARMED/DISARMED state it was in before 
power off. Also, the reader restores its original ARMED/DISARMED state after exiting the programming mode. 
After erasure of the reader’s memory the reader always returns to ARMED state 

6.3

 

Arming and Disarming of Reader (rearming) 

The action that changes the reader’s state from ARMED to DISARMED and vice versa will be referred to as 
REARMING, the term “arming” should be understood as switching the reader into the ARMED state, and the 
term “disarming” as switching the reader into the DISARMED state. 

Содержание PRT42

Страница 1: ...Installation and Programming Guide PRT42 and PRT42 BK Indoor Access Control Terminals Firmware v72 00...

Страница 2: ...ory Reset Procedure Programming MASTER and INSTALLER cards 10 5 2 1 Factory Default Settings 10 5 3 Installer Programming Mode 10 5 4 User Programming Mode 11 5 4 1 Programming Commands 11 5 4 2 Progr...

Страница 3: ...other uses them for communication with an external XM 2 I O module and a second PRT reader see wiring diagrams An access control installation containing two PRT readers one at the entry the other at...

Страница 4: ...the PRT reader uses 26 34 42 or 66 bits to transmit a code read in from the presented card or a PIN entered Note For card and PIN codes longer than the number of bits available in the selected data t...

Страница 5: ...l LEDs are flashing it indicates that the reader lost communication with host ACU unit Each entry of PIN code must be followed by pressing the key which is treated as an end of PIN code The PRT42 read...

Страница 6: ...set to ID 0 Note The XM 2 I O expander module connected to PRT reader must be set to address ID 5 jumpers JP1 and JP3 closed 3 2 2 Simple stand alone operation mode In this mode the reader s CLK and...

Страница 7: ...s with two readers to be mounted on opposite sides of the same wall and along the same geometrical axis place a metal plate between them and make sure none of them has direct contact with it at least...

Страница 8: ...ethods and functions described for the keypad readers are also valid for the no keypad readers the only difference being that one press of a desired key on keypad reader is simulated on a no keypad re...

Страница 9: ...function Reader Disarmed Output User identification mode on the primary reader Card or PIN User identification mode on the secondary reader Card or PIN Option Door Alarm Indication On Internal Buzzer...

Страница 10: ...activates door lock 3 Ready Input when line shorted to supply minus reader can be armed C10 0 1 Primary main Reader Identification Mode 0 Card or PIN identification 1 Card PIN identification C11 0 1 S...

Страница 11: ...r with the specified ID and then deletes both his PIN and his card Once completed a new user can be programmed to use this ID index 0 Delete all users in the system Deletes all users including their c...

Страница 12: ...gramming command Example 5 Rearm the reader by presenting a TOGGLE User card Read your TOGGLE User card once accepted the reader grants you access and its SYSTEM LED starts blinking With the SYSTEM LE...

Страница 13: ...Mode INSTALLER user has no PIN code MASTER A card of this user allows to enter User Programming Mode MASTER user has no PIN code NORMAL Users of this type are solely authorized to unlock the door The...

Страница 14: ...D mode and has set an option Access Disabled When Reader Armed If the second scenario occurs the TOGGLE or TOGGLE LTD user may use its identifier Card PIN or both when Card PIN mode is active to switc...

Страница 15: ...on Memory error or MASTER or INSTALLER cards not programmed memory reset necessary This signal is accompanied by LED SYSTEM steady ON Legend one long signal One short signal beep LED Indications in St...

Страница 16: ...tion Interface The reader operates in Host controlled mode it needs to be connected to a master unit ACU which requires Magstripe data format ONLINE Mode 26 bit WIEGAND Communication Interface The rea...

Страница 17: ...s compatible with HID 5355 series readers option With Parity Each key transmitted separately no control bits added Each key pressed on the reader s keypad is immediately transmitted to the master cont...

Страница 18: ...PRT42 Grey RFID PIN reader light grey PRT42 BK Grey RFID reader light grey RM 2 Relay module The RM 2 offers two relays with one NO NC contact 5A 24V rated relay contacts protected with overvolatge e...

Страница 19: ...me Reader location ID Number Card number PIN Type User Name Master Installer 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 4...

Страница 20: ...name Reader location ID Number Card number PIN Type User Name 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 1...

Страница 21: ...PRT42 and PRT42 BK v1 0 fv72 EN Rev C 22...

Страница 22: ...PRT42 and PRT42 BK v1 0 fv72 EN Rev C 23...

Страница 23: ......

Страница 24: ...PRT42 and PRT42 BK v1 0 fv72 EN Rev C 25...

Страница 25: ...PRT42 and PRT42 BK v1 0 fv72 EN Rev C 26...

Страница 26: ......

Страница 27: ...tacking networks Roger does not warrant that the Product will be free of vulnerability to intrusion or attack This warranty does not cover repair or replacement where normal use has exhausted the life...

Страница 28: ......

Страница 29: ...may be reached at 48 55 2670126 or support roger pl Monday through Friday 8 00 A M to 4 00 P M GMT 1 You can also contact the Technical Support Department by fax at 48 55 2720133 If it is determined t...

Страница 30: ...form in order to avoid damages during transit You are advised to get proof of delivery 12 Some repairs may be chargeable and you will receive formal advice if this is the case 13 If product returned a...

Отзывы: