MCX402-BRD Operating Manual
04.12.2020
10/13
Battery test period [min.]
Parameter defines time between battery tests. Range: 0-250. When
set to 0 then testing is disabled. Default value: 10.
Input types
IN1-IN8
Parameter defines input type. Range: [0]: NO, [1]: NC. Default value:
[0]: NO.
Input comments
IN1-IN8
Parameter defines any text or comment which corresponds to the
object. It is later displayed in VISO program.
Output polarity
REL1, REL2, IO1, IO2
Parameter defines polarity of output. Normal polarity means that the
output by default is switched off while Reversed polarity means that
the output by default is switched on. Range: [0]: Normal polarity, [1]:
Reversed polarity. Default value: [0]: Normal polarity.
Output comments
REL1, REL2, IO1, IO2
Parameter defines any text or comment which corresponds to the
object. It is later displayed in VISO program.
Object comments
DEV
Parameter defines any text or comment which corresponds to the
device. It is later displayed in VISO program.
Wiegand terminal 1 / Wiegand terminal 2*
Terminal enabled
When option is enabled then Wiegand terminal 1/2 is operated.
Range: Yes, No. Default value: Yes.
Keypad enabled
When option is enabled then keypad on Wiegand terminal 1/2 is
operated. Range: Yes, No. Default value: Yes.
AF type
Parameter defines authentication factor type returned by terminal.
Default value: [16]: Number 40bits.
AF class
Parameter defines authentication factor class returned by terminal.
Default value: [0002]: EM.
KBD comment
Parameter defines any text or comment which corresponds to the
object. It is later displayed in VISO program.
CDI comment
Parameter defines any text or comment which corresponds to the
object. It is later displayed in VISO program.
Card code length
Parameter defines type of Wiegand 26-66bit interface. Range:0-66.
Default value: 26.
Card code reverse order
When option is enabled then expected card code returned by terminals
is in reverse order. Range: Yes, No. Default value: No.
PIN format
Parameter defines format of PIN returned by terminal. Range: [0]:
None, [1]: BIN, [2]: BCD, [3]: HEX. Default value: [0]: None.
PIN length
Parameter defines expected code length that is recognized as PIN.
Range: 0
– no verification, 1-15 – verification off, 16-66 – verification
on. Default value: 0.
PIN reverse order
When option is enabled then expected PIN returned by terminal is in
reverse order. Range: Yes, No. Default value: No.
Single key press
When option is enabled then reader transmits the whole PIN to
controller. When option is disabled then reader transmits every