MCX102-BRD Operating Manual
04.12.2020
7/12
Fig. 5 Typical door control with Wiegand interface reader
4.
C
ONFIGURATION
Low level configuration (RogerVDM)
The purpose of low level configuration is to prepare device for operation in RACS 5 system.
Programming procedure with RogerVDM software:
1. Connect the device to RUD-1 interface (fig. 6) and connect the RUD-
1 to computer’s USB port.
2. Start RogerVDM program, select
MCX v1.x
device, firmware version,
RS485
communication channel
and serial port with RUD-1 interface.
3. Click
Connect,
the program will establish connection and will automatically display
Configuration
tab.
4. Enter unoccupied RS485 address in range of 100-115, enable Wiegand or PRT terminals, configure
input types (e.g. NC for IN1 according to fig. 4) and other settings according to requirements of specific
installation.
5. Click
Send to Device
to update the configuration of device.
6. Optionally make a backup by clicking
Send to File…
and saving settings to file on disk.