background image

HRT82TS Installation Guide Rev.C.doc

 

2016-10-10 

 

 

2/9 

 

1.

 

I

NTRODUCTION

 

This  manual  contains  minimum  information  that  is  necessary  to  properly  install  device.  Following 
documents supplement this manual: 

 

Functional description of HRC series controllers 

 

Installation guide for HRC series controllers 

In  order  to  acquire  the  first  one  it  is  necessary  to  obtain  Roger  consent  and  sign  non-disclosure 
agreement (NDA). The second one is available at 

www.roger.pl

.  

2.

 

D

ESCRIPTION AND SPECIFICATION

 

HRT82TS  temperature  sensor  module  is  peripheral  device  used  in  a  hotel  system  based  on  HRC 
series controllers. The module communicates with controller using RACS CLK/DTA bus and enables 

room  temperature  readout  allowing  the  controller  to  control  air  conditioning  and/or  heating 
systems. Interchangeably, room temperature can also be read by means of such devices with built-
in temperature sensors as HRT82AC air conditioning control panel and HRT82MF-CH card holder.  

Table 1. Specification 

Supply voltage 

Nominal 12VDC, min./max. range 10-15VDC 

Average current 

consumption  

25mA 

Tamper resistance 

Isolated contact, NC type (normally closed when enclosure is assembled 
and attached), 24V/50mA 

Distance 

Between controller and HRT device (RACS CLK/DTA): max. 150m 

Environmental class 
(acc. to EN 50131-1) 

Class II, indoor general conditions, temperature: -10°C- +50°C, relative 
humidity: 10 to 95% (no condensation) 

IP code 

IP41 

Dimensions HxWxD 

85 x 85 x 22 mm  

Weight 

~ 100g 

Certificates 

CE 

 

3.

 

I

NSTALLATION

 

3.1 Terminals and connection diagram 

 

Fig. 1 HRT82TS temperature sensor 

Содержание HRT82TS

Страница 1: ...re version 1 0 8 23 or newer Hardware version 1 0 Document version Rev C 2016 ROGER sp z o o sp k All rights reserved This document is subject to the Terms of Use in their current version published at the www roger pl website of the Roger sp z o o sp k company hereinafter referred to as ROGER ...

Страница 2: ...bles room temperature readout allowing the controller to control air conditioning and or heating systems Interchangeably room temperature can also be read by means of such devices with built in temperature sensors as HRT82AC air conditioning control panel and HRT82MF CH card holder Table 1 Specification Supply voltage Nominal 12VDC min max range 10 15VDC Average current consumption 25mA Tamper res...

Страница 3: ...nominal power supply The power must be connected to 12V and GND terminals Additionally the GND terminal is used as reference potential for the RACS CLK DTA bus HRT82TS power supply can be provided by connection to buffer power supply unit e g PS 15DR PS20 or connection to AUX output of HRC402DR controller see fig 2 Backup battery connected to power supply unit or directly to HRC402DR controller ca...

Страница 4: ... of front panel and base which are factory assembled and require manual disassembly prior to installation according to fig 4 Installation guidelines Install device on wall far from sources of heat and moisture It is recommended to install device on Ø60mm flush mounting box Front panel and base must be properly oriented in order to ensure functioning of tamper resistance All electric connections mu...

Страница 5: ...HRT82TS Installation Guide Rev C doc 2016 10 10 5 9 Fig 4 HRT82TS latches and wall mounting ...

Страница 6: ...on interface according to fig 5 2 Place jumper on MEM pins 3 Restart the device place and remove jumper on RST pins or switch power supply off and on 4 Install and start RogerVDM software 5 In the opened window select device firmware version communication channel and serial port with connected RUD 1 see fig 6 6 Select Connect button the software shall establish connection with the device and autom...

Страница 7: ...en failure is not signalled at all 4 2 Firmware update HRT82TS firmware can be updated with RogerVDM available at www roger pl after connection to RUD 1 communication interface Firmware update procedure 1 Connect device to RUD 1 communication interface according to fig 5 2 Install and start RogerVDM software 3 Close Select Device window 4 In top menu select Tools Update firmware 5 In the opened wi...

Страница 8: ...see 4 1 5 TROUBLESHOOTING Table 4 Troubleshooting Issue Visual indication Acoustic indication Solution No communication with controller Front panel icon backlight blinking 1 Check if RACS CLK DTA bus is properly connected wires are undamaged and the bus does not exceed 150 m All devices connected to particular RACS CLK DTA bus should have common supply minus GND 2 Check if the controller is proper...

Страница 9: ...is obliged to deliver equipment to the designated collection points of electric and electronic waste For detailed information on recycling contact your local authorities waste disposal company or point of purchase Separate collection and recycling of this type of waste contributes to the protection of the natural resources and is safe to health and the environment Weight of the equipment is specif...

Отзывы: