Roger H70/103AC Скачать руководство пользователя страница 7

79

Courtesy light time

0 → OFF
1 → IMPULSIVE, the output is on for a short time when it starts the movement 
2 → the output is on during all movement time 

  3-90 → SECONDS after the end of the movement, in which the output is on and moreover it is on during all 

movement time 

92-99 → from 92 the second number indicates the MINUTES after the end of the movement, in which the 

output is on and moreover it is on during all movement time (from 2 to 9 minutes) 

2

8A

Configuration clock input (ORO)

, closing the contact it causes an opening of the gate, while the opening 

of the contacts causes the closing of the gate. You can choice 2 configurations:
       0 → When the clock input (ORO) is closed, it ignores all inputs 
       1 → When the clock input (ORO) is closed, it accepts all inputs 

0

90

Recover setting default

To recover all parameters setted on Roger Technology (look the last column of this table), You have to push 
the selection button and after the 2 scrolling buttons togheter. If this process is done in the correct way the 
display shows You the parameter LL.. 

n0

Serial number

00-FF → control unit model

n1

Serial number

00-99 → production year

n2

Serial number

00-52 → production week

n3

Serial number

00-99 → 1° progressive number

n4

Serial number

00-99 → 2° progressive number

n5

Serial number

00-99 → 3° progressive number

n6

Serial number

00-99 → software version

o0

Movements number

00-99 → X 10.000 movements

o1

Movements number

00-99 → X 100 movements

h0

Motor activation hours

00-99 → X 100 hours

h1

Motor activation hours

00-99 → hours

d0

Power on in days of control unit

00-99 → X 100 days 

d1

Power on in days of control unit

00-99 → days

P1

Password P1

00-99

00

P2

Password P2

00-99

00

P3

Password P3

00-99

00

P4

Password P4

00-99

00

CP

Change password

To change the password, You have to insert the old one to deblock the control unit. After we insert the new 
one, we select the paramenter CP (change password), we push the button S3 (00 flashing) and finally we 
have to push togheter the buttons  S1 and S2. On the beginning the password setted is 00 00 00 00. If You 
lose the password, You can deblock the control unit contacting the service.

15

Содержание H70/103AC

Страница 1: ...DI COMANDO CONTROL UNIT H70 103AC ISTRUZIONI E AVVERTENZE PER L INSTALLATORE INSTRUCTIONS AND RECOMENDATIONS FOR THE INSTALLER INSTRUC ES E ADVERT NCIAS PARA A INSTALA O ISTRUCTIONS ET AVERTISSEMENT...

Страница 2: ...10 minutes without any pushing display comes on standby and it shows You only the POWER segment with intermittent light picture 5 SHOWING INPUT MODE When the power comes back or pushing one of the 3...

Страница 3: ...o make the learning of the travel lenght You have to manually fit the gate on intermediate position after You have to select the parameter number 10 set the value to 1 and You have to confirm it by S3...

Страница 4: ...10 Length travel learning You have to do that when the gate is in the middle of his travel To make the travel lenght learning You have to set the value to 1 and You have to confirm it by S3 after we s...

Страница 5: ...n opening 2 52 A When the gate is closed it allows an opening with the beam of photocell 1 FT1 interrupted 0 gate closed NOT allowed the opening by the beam of photocell FT1 interrupted 1 gate closed...

Страница 6: ...io receiver channel 0 PP 1 PEDESTRIAN 2 OPEN 3 CLOSE 4 STOP 5 COURTESY the normal functionning is not enable the relay is only managed by the radio receiver 6 COURTESY PP the normal functionning is no...

Страница 7: ...If this process is done in the correct way the display shows You the parameter LL n0 Serial number 00 FF control unit model n1 Serial number 00 99 production year n2 Serial number 00 52 production wee...

Страница 8: ...ally close contact PHOTOCELL 1 CONNECTION FT2 COM normally close contact PHOTOCELL 2 CONNECTION SC COM 24Vcc MAX 2W OPEN GATE LIGHT CONNECTION slow flashing in opening fast flashing in closing and fix...

Страница 9: ...4 S2 S3 RELEASE INPUT LIMIT SWITCH INPUT ENCODER INPUT COM COMMON AP OPEN CH CLOSE PED PEDESTRIAN ORO CLOCK S1 ANT ANTENNA COM COMMON PP STEP BY STEP ST STOP COS1 SAFETY EDGE 1 COS2 SAFETY EDGE 2 FT1...

Отзывы: