Roger H70/103AC Скачать руководство пользователя страница 2

TECHNICAL DETAILS

1 motor 230V~ ±10% 50Hz,  2200W max

Working temperature from -10 to +55°C

Flashing light 1A max (tension free contact )

Courtesy 2A max (tension free contact)

Open gate led 24Vcc 2W max

Accessories current  300mA max on 24Vcc

2 levels of slow-down speed

8 levels of start up torque

8 levels of normal torque on travel

8 levels of force on slow-down

Electronic stop with 8 levels of stopping torque

99 sensibility levels to find an obstacle on normal 
speed 

99 sensibility levels to find an obstacle on slow-down 
speed 

Software selection on right or left motor

Software exclusion of input N.C. not used

Configurable input clock

2 inputs for safety edge

1° radio channel used for different input/output

2° radio channel used for different input/output

Flashing light output free of tension

Courtesy light output free of tension

Travel checking by encoder and limit switch

Automatically learning of the travel

Works without limit switch (it is necessary encoder)

5 modes of input functioning of step by step

Password to protect the configuration

Memorized of n° of movement

Memorized working time of the motor

Memorized working time of control unit

Showed serial number of control unit

CONFIGURATION OF THE PARAMETERS

The configuration of the control unit is made changements on the 
predefinied  value associated on the parameter through 3 buttons, 
S1, S2 e S3, and it showed on the dispaly (picture 1). The control 
unit is supplied with default value, please look on last columns on 
the attached parameters table.

STANDBY MODE

After 10 minutes without any pushing, display comes on standby, and it shows You only the POWER segment with  
intermittent light (picture 5).

SHOWING INPUT MODE

When the power comes back, or pushing one of the 3 buttons, the display will show You the inputs state.
From each input of the control unit is associated a segment on display (picture 5). If the input is closed the segment 
is on, if the input is open the segment is off, if the input is not enable (short circuited) on software the segment  
flashing 
The 2 radio channels can be associated to different comands (parameters 76 e 77), when we activate one of the  
radio channel the control unit will show You the referent segment.

SHOWING PARAMETERS MODE

When we push the buttons S1 or S2, the control unit changes from input showing to parameters showing (picture  
2).
The parameter is showed on the first two numbers on the left of the display by intermittent light, while the value of  
the parameter is showed on the right of the display by fixed light. 
When we push the button S2 the control unit shows You the next parameter and his value from the first to the last. 
By the parameter LL=0 the control unit shows You only the basic parameter,  while  by LL=1 the control unit shows  
You all the parameters.
When we achieve the last parameter (CP), another pushing of the button S2 the control unit will show You the input  
showing, and if we push again the button the control unit will show You the parameters showing yet. By the button 
S1 we have the same functions but in the opposite way, from the last to the first.

10

     INPUT

LL

02

03

...

P4

CP

S2

S2

S2

S2

S2

S2

     INPUT

LL

02

03

...

P4

CP

S1

S1

S1

S1

S1

S1

S1

SELECTION BUTTON                  SCROLLING BUTTON

S3

S2 

+

PARAMETER NUMBER            PARAMETER VALUE

S1 

-

Picture  1

S2

Picture 2

  

GB

Содержание H70/103AC

Страница 1: ...DI COMANDO CONTROL UNIT H70 103AC ISTRUZIONI E AVVERTENZE PER L INSTALLATORE INSTRUCTIONS AND RECOMENDATIONS FOR THE INSTALLER INSTRUC ES E ADVERT NCIAS PARA A INSTALA O ISTRUCTIONS ET AVERTISSEMENT...

Страница 2: ...10 minutes without any pushing display comes on standby and it shows You only the POWER segment with intermittent light picture 5 SHOWING INPUT MODE When the power comes back or pushing one of the 3...

Страница 3: ...o make the learning of the travel lenght You have to manually fit the gate on intermediate position after You have to select the parameter number 10 set the value to 1 and You have to confirm it by S3...

Страница 4: ...10 Length travel learning You have to do that when the gate is in the middle of his travel To make the travel lenght learning You have to set the value to 1 and You have to confirm it by S3 after we s...

Страница 5: ...n opening 2 52 A When the gate is closed it allows an opening with the beam of photocell 1 FT1 interrupted 0 gate closed NOT allowed the opening by the beam of photocell FT1 interrupted 1 gate closed...

Страница 6: ...io receiver channel 0 PP 1 PEDESTRIAN 2 OPEN 3 CLOSE 4 STOP 5 COURTESY the normal functionning is not enable the relay is only managed by the radio receiver 6 COURTESY PP the normal functionning is no...

Страница 7: ...If this process is done in the correct way the display shows You the parameter LL n0 Serial number 00 FF control unit model n1 Serial number 00 99 production year n2 Serial number 00 52 production wee...

Страница 8: ...ally close contact PHOTOCELL 1 CONNECTION FT2 COM normally close contact PHOTOCELL 2 CONNECTION SC COM 24Vcc MAX 2W OPEN GATE LIGHT CONNECTION slow flashing in opening fast flashing in closing and fix...

Страница 9: ...4 S2 S3 RELEASE INPUT LIMIT SWITCH INPUT ENCODER INPUT COM COMMON AP OPEN CH CLOSE PED PEDESTRIAN ORO CLOCK S1 ANT ANTENNA COM COMMON PP STEP BY STEP ST STOP COS1 SAFETY EDGE 1 COS2 SAFETY EDGE 2 FT1...

Отзывы: