Roger H70/103AC Скачать руководство пользователя страница 3

PARAMETER CHANGE MODE

If we select the parameter to be modified, pushing the button S3 we can modified the parameter. If the control unit 
is protected by password, the parameter could be only showed but not modified, we can modified the parameter if  
we enter the password (P1,P2,P3,P4).
The parameter is showed on the first two numbers on the left of the display by fixed light, while the parameter value  
that we can modify is showed on two numbers on the right of the display by flashing light.
We can modify the value of the parameter by the buttons S1 and S2, we can choice one of the value indicated (look  
the parameter table indicated).
If we push the button S3 we confirm the selection and we come back on the parameter showing mode.
If we are on parameter modifing mode and we do not push any button, after 30 sec. the control unit automatically  
comes back on parameter showing mode.
When we change the parameter value, these changements are automatically done if the gate uses the closing limit 
switch (totaly close), otherwise You have to power off and after You have to power on.

STANDARD INSTALLATION

You   have   to   make   the   electric   connections   of   the   accessories,   of   the 
comands and of the safety elements  (pic. 4).

Make   attention   when   You   connect   the   flashing   light   and   the   courtesy 
because they are on tension free contact  (pic. 3).

Make the power connection.

It is not necessary to make short circuit to any safety inputs that we do not 
use, like LIMIT SWITCH (parameter 72), PHOTOCELLS (parameters 50, 51, 
53 and 54) and SAFETY EDGE (parameters 73 and 74),  because it can get  
off by software(the corrisponding segment will flash on input showing). You 
have to short circuit only to the STOP parameter, if You do not use it.

Use the parameter number 71 to choice the side of the motor: right or left (look it on the internal). The standard 
option is on right side (71 = 1), if the motor is installed on left side 71 = 0. When You make this changement You  
have to power off and after You have to power on.

It is necessary to make the learning of the travel lenght: You have to manually fit the gate on intermediate  
position, after You have to select the parameter number 10,  set the value to 1 and You have to confirm it by S3,  
after we see flashing all numbers and push the  PP. The motor will make a complete  opening and  closing in 
slow-down, if the process is made in right mode, the parameter comes back to 0. If the display show You. If the 
display shows You _E, it means that the process is failed, and You have to repeat it; If the process failed again, 
You have to increase the torque (parameter 32), or decrease the sensibility (parameter  43) and repeat the 
learning.

REFERENCES CONTROL STATUS

The control unit is on references control status in 3 cases:

mechanical release opening and manual movement;

after black-out

when the limit switch is not installed and the gate finds an obstacle for three continuation times in the same 
place. In this case the control unit waits for a comand of the installer, when the control unit receives it opens in 
slow-down until to mechanical stop or limit switch, when the control unit receives another comand it closes in 
slow-down until to mechanical stop or limit switch. If the process is made in the right way the control unit comes  
back to normal functionning, otherwise it continues to slow-down movements until one of the references has 
been verified. 

PASSWORD

There is the possibility to select a password, composed by 4 parameters P1, P2, P3 e P4. If in the 4 parameters we  
do not select the numbers corrisponding to the password, it is not possible to modified all the other parameters, we 
can only view them.
The password settled by us is  00 00 00 00, so the control unit is deblocked.
To change the password it is necessary deblock the control unit pushing in the 4 parameters P1, P2, P3 e P4 the 
old password, after we have to insert the numbers of the new one, we select the paramenter CP, we push the  
button S3 (00 flashing) e finally we have to push together the buttons  S1 and S2.
When the control unit is deblocked, to block it again You have to power off or waiting the stand-by of the display (it  
showes only the POWER led flashing).

11

    COR    LAM

         F      N

Picture 3

COURTESY   FLASHING LIGHT

Содержание H70/103AC

Страница 1: ...DI COMANDO CONTROL UNIT H70 103AC ISTRUZIONI E AVVERTENZE PER L INSTALLATORE INSTRUCTIONS AND RECOMENDATIONS FOR THE INSTALLER INSTRUC ES E ADVERT NCIAS PARA A INSTALA O ISTRUCTIONS ET AVERTISSEMENT...

Страница 2: ...10 minutes without any pushing display comes on standby and it shows You only the POWER segment with intermittent light picture 5 SHOWING INPUT MODE When the power comes back or pushing one of the 3...

Страница 3: ...o make the learning of the travel lenght You have to manually fit the gate on intermediate position after You have to select the parameter number 10 set the value to 1 and You have to confirm it by S3...

Страница 4: ...10 Length travel learning You have to do that when the gate is in the middle of his travel To make the travel lenght learning You have to set the value to 1 and You have to confirm it by S3 after we s...

Страница 5: ...n opening 2 52 A When the gate is closed it allows an opening with the beam of photocell 1 FT1 interrupted 0 gate closed NOT allowed the opening by the beam of photocell FT1 interrupted 1 gate closed...

Страница 6: ...io receiver channel 0 PP 1 PEDESTRIAN 2 OPEN 3 CLOSE 4 STOP 5 COURTESY the normal functionning is not enable the relay is only managed by the radio receiver 6 COURTESY PP the normal functionning is no...

Страница 7: ...If this process is done in the correct way the display shows You the parameter LL n0 Serial number 00 FF control unit model n1 Serial number 00 99 production year n2 Serial number 00 52 production wee...

Страница 8: ...ally close contact PHOTOCELL 1 CONNECTION FT2 COM normally close contact PHOTOCELL 2 CONNECTION SC COM 24Vcc MAX 2W OPEN GATE LIGHT CONNECTION slow flashing in opening fast flashing in closing and fix...

Страница 9: ...4 S2 S3 RELEASE INPUT LIMIT SWITCH INPUT ENCODER INPUT COM COMMON AP OPEN CH CLOSE PED PEDESTRIAN ORO CLOCK S1 ANT ANTENNA COM COMMON PP STEP BY STEP ST STOP COS1 SAFETY EDGE 1 COS2 SAFETY EDGE 2 FT1...

Отзывы: