5/15 

 

 

 

Fig. 2 Typical connection diagram for CPR32-SE-BRD v3.0 network controller 

Содержание CPR32-SE-BRD

Страница 1: ...version 3 0 5133 or newer Hardware version 3 0 Document version Rev B 2016 ROGER sp z o o sp k All rights reserved This document is subject to the Terms of Use in their current version published at th...

Страница 2: ...3 3 Power supply 6 3 4 Communication with CPR 8 3 5 Input and output lines 8 3 5 1 Inputs 8 3 5 2 Relay outputs 8 3 5 3 General purpose outputs 8 3 6 Installation guidelines 9 4 Configuration 9 4 1 C...

Страница 3: ...erns PRxx1 series controllers The network controller is equipped with RS485 port which is used for direct communication with access controllers and for communication with computer PR Master software u...

Страница 4: ...IN8 input line P2 Power supply for CPR IO1 IO1 output line COM REL1 relay common terminal IO2 IO2 output line NC REL1 relay output NC IN1 IN1 input line NO REL1 relay output NO IN2 IN2 input line CLK...

Страница 5: ...CPR32 SE BRD v3 0 User Manual 2020 10 08 5 15 Fig 2 Typical connection diagram for CPR32 SE BRD v3 0 network controller...

Страница 6: ...roller is designed for power supply from 230VAC 18VAC transformer with minimal power output 25VA but it can also be supplied with 12VDC The connection of power supply is shown in fig 4 and fig 5 If CP...

Страница 7: ...CPR32 SE BRD v3 0 User Manual 2020 10 08 7 15 Fig 4 CPR32 SE BRD v3 0 and PR402DR PR411DR controllers supplied with 18VAC Fig 5 CPR32 SE BRD v3 0 and PRxx1 PRxx2 series controllers supplied with 12VDC...

Страница 8: ...istors terminators connected at the ends of transmitting lines are not required In most cases communication works with any cable type standard telephone cable shielded or unshielded twisted pair etc b...

Страница 9: ...n bus including connected access controllers CPR32 SE BRD network controller and communication interface e g UT 2USB the installer can proceed with installation and configuration of PR Master software...

Страница 10: ...CPR off and on Menu Settings Inputs Outputs In the window opened by means of this option it is possible to assign functions to CPR32 SE BRD inputs and outputs Additionally in case of inputs the admin...

Страница 11: ...ed at all controllers doors within subsystem network 12 Clear all alarms in subsystem ON monitored When the input is activated then all alarms in CPR32 SE BRD and controllers within particular subsyst...

Страница 12: ...es controllers within the subsystem network 73 Alarm in CPR The output is activated for 3 minutes if Tamper Alarm or Power supply alarm is raised The function 67 operates as a sum of 81 and 82 functio...

Страница 13: ...ut is activated for 3 minutes when the event memory buffer is filled in 75 90 Low battery 3 min The output remains activated for 3 minutes if charge level of backup battery connected to CPR32 SE BRD u...

Страница 14: ...d with CPR32 SE BRD network controller connected to PC through such serial interfaces as UT 2USB RUD 1 or UT 4 with virtual serial port then CPR is erroneously detected by Windows as Microsoft Serial...

Страница 15: ...have a negative impact on the environment and health The user is obliged to deliver equipment to the designated collection points of electric and electronic waste For detailed information on recycling...