• The photocells are configured by default to operate with
a power supply voltage of 24 V ac/dc.
To change the power supply of 12 V ac/dc, short circuit
the two terminal zones
C
on the back of the printed
circuit board with a spot of solder, as shown in fig. 3.
• The maximum range is set in the factory to 10 m.
To increase the range to 15 m, cut the copper jumper
connector
E
on the back of the receiver
RX
as shown in
fig. 3.
• To prevent malfunctions caused by interference and
reflections, is insufficient to install the photocells as
shown in fig. 4, but we suggest to use synchronised
photocells.
• Synchronisation
. Synchronisation makes it possible to
install two pairs of ROGER TECHNOLOGY photocells in
close proximity without the risk of interference.
To enable synchronisation, remove the jumpers
P1
from
the
TX
photocells and connect the power feed from the
electronic controller to the
0V
and
24V
terminals with
crossed wires, as shown in fig. 2.
NOTE
: Synchronisation is not available for photocells
configured for 12-24 V direct current power.
1. Fasten the
TRIX
pillars as indicated in the installation
manual.
2. Calculate the cable length necessary in relation to the
height of the
TRIX
pillar and the number of photocells
in the installation (see fig. 5).
3. The photocells may be installed in one of the three
channels on the
TRIX
pillar (see fig. 6 and 8).
4. With the system disconnected from mains electricity,
make the electrical connections as shown in fig. 1 and
2: connect power to the photocells, observing the
correct polarity indicated, and connect the terminals
C-NC
to the terminals
COM-FT
respectively on the
electronic controller.
NOTA
: if synchronisation is enabled, the power cables
must be crossed, see fig. 2.
5. Close the photocell housings and fasten with the screws
included B, as shown in fig. 7.
6. Fit the collar
A
.
7. Route the cables in the specific channels (fig. 8).
8. Fit the screws on the collar (part
G-H
, fig. 9), without
tightening.
9. Set the
RX
receiver and the
TX
transmitter at the
required height, aligning the two devices optically.
10. The red LED
L
on the
RX
receiver indicates signal
strength and that the
TX
and
RX
devices are correctly
aligned. The brighter the LED, the stronger the signal
received and the more precisely the devices are aligned.
11. Fasten the collar to the pillar with the self-tapping
screw (part
I
fig. 9).
12. Adjust the orientation of the light beam with the
adjuster screw
M
, as shown in fig. 10.
13. Fasten the photocell definitively with the screw
N
.
14. Close the
TRIX
pillar as shown in fig. 11.
7
Initial testing
1. Switch the controller unit on. The
PW
LED illuminates.
2. Interrupt the light beam between the photocells with a
50 mm diameter cylindrical object. The automatic door
or gate must stop or reverse direction. The red LED
L
extinguishes.
3. Stand near the
TX
photocell and interrupt the light
beam.
4. Repeat the procedure for the
RX
photocell and for any
other pairs of photocells installed.
8
Maintenance
Perform scheduled maintenance every 6 months.
Check that the photocells are clean and are working
correctly. In particular, keep the outer surfaces of the
RX
receiver and the
TX
transmitter clean.
If any dirt, moisture, insects or other obstructions are
found, clean the photocell and repeat the initial testing
procedure.
If any corrosion is found on the printed circuit board,
evaluate if it is necessary to replace the board itself.
9
Disposal
This product may only be uninstalled by qualified
technical
personnel,
following
suitable
procedures for removing the product correctly
and safely. This product consists of numerous
different materials. Some of these materials
may be recycled, while others must be disposed
of correctly at the specific recycling or waste management
facilities indicated by local legislation applicable for this
category of product. Do not dispose of this product as
domestic refuse. Observe local legislation for differentiated
refuse collection, or hand the product over to the vendor
when purchasing an equivalent new product.
Local legislation may envisage severe fines for the incorrect
disposal of this product.
Warning!
some parts of this
product may contain substances that are harmful to the
environment or dangerous and which may cause damage
to the environment or health risks if disposed of incorrectly.
10
Declaration of Conformity
I the undersigned, as acting legal representative of the
manufacturer:
Roger Technology
Via Botticelli 8, 31021 Bonisiolo di Mogliano V.to (TV)
hereby DECLARE that the appliance described hereafter:
Description: Photocell for automatic doors and gates
Model: T90
Is conformant with the legal requisites of the following di
-
rectives:
•
2004/108/CEE
• 2006/95/CEE
• 2011/65/CEE
and that all the standards and/or technical requirements
indicated as follows have been applied:
EN 61000-6-3; EN 61000-6-2
Last two figures of year in which marking was applied
|
15.
Place
: Mogliano V.to
Date
: 20-05-2015 Signature
Содержание T90/F2S
Страница 3: ...3 6 8 7 A B B F 1 1 1 2 2 2 ...
Страница 4: ...4 9 10 11 M N G H I 30 30 ...