background image

 

Operating instructions 

BA_M4301_EN 

 

 

 

5 / 18 

 

 

 CAUTION 

 

 

Stroke module, pump lever not operate on bottom base 
plate

 

Foot pedal is pressed down below the lower edge of the base 
plate. 
• 

The customer has to make sure that this will be prevented 
by the concrete floor or a corresponding base plate con-
necting construction. 

 

 

 

1.

 

Install the product so that for the required cleaning and 
maintenance works there is all around a clearance zone of 
at least 700 mm. 

2.

 

The product has to be mounted horizontally on a plane and 
solid concrete floor (concrete strength grade B 25) or a rigid 
connecting construction of the customer (flatness 0.20 mm). 

3.

 

Fasten the bottom plate of the product with hexagon socket 
head cap screws ISO 4762 - M10 onto the concrete floor or 
the connecting construction of the customer. 

4.

 

For this purpose professionally insert into the concrete floor  
heavy-duty dowels (e.g. Fischer part-no.:  SL M-10 N). 

 

 

 

Figure 3: principle of fixing 
 

1

 

Concrete floor or con-
necting construction 

2  Foot pedal  

3

 

Bottom plate 

4

 

Top plate 

 

 

 

 

1.10.3 

Mounting of the customer's connecting construc-
tion 

 

 WARNING 

 

Injury due to overturning product! 

• 

Overturning product due to eccentric load provided by the 
user! 

• 

The centre of gravity of the user's load must be within the 4 
fixing screws of the bottom plate. 

• 

When introducing torques within the load limit (see technical 
characteristics) we recommend to use an additional base 
plate (accessory) and to secure this plate correctly. 

 

 

 

1.

 

For fixing of the customer's connecting construction there 
are 4 bore holes (for M10 - 

 10.5 mm ) at the top plate. 

 

All provided bore holes have to be used! 

2.

 

Fasten the connecting construction at the top plate. 

 

 

 Note 

 

 

Dangers due to the connecting construction of the cus-
tomer 

Dangers due to the connecting construction of the customer, as 
e.g. squeezing points have to be excluded by the customer's 
design. 

 

 

 

1.11 

Start up 

 

 WARNING 

 

Poisoning due to contact with hydraulic oil! 

Wear, damage of the seals, ageing and incorrect mounting of 
the seal kit by the operator can lead to escapes of oil. 
Incorrect connection can lead to escapes of oil at the ports. 
• 

For handling with hydraulic oil consider the material safety 
data sheet. 

• 

Wear protection equipment. 

 

 

 

1.

 

Check tight seat (check tightening torque of the fixing 
screws). 

 

1.11.1 

Operation 

 

 WARNING 

 

Injuries due to non-compliance of the operating instruc-
tions! 

• 

The product may only be operated, if the operating instruc-
tions - especially the chapter "Safety instructions" have 
been read and understood. 

 

Injury by crushing! 

Components of the product make a movement while they are in 
operation. 
• 

This can cause injuries. 

• 

Keep parts of the body and items out of the working area! 

 

Injuries due to misuse, incorrect operation or abuse! 

Injuries can occur if the product is not used within the intended 
use and the technical performance data. 
• 

Before start up, read the operating instructions! 

 

 

 

 

 

The operator is obliged to report immediately any changes at 
the product that may affect the safety to the safety expert or to 
the person who is responsible for safety and to stop operating 
the product. 
 

Содержание Shop-Floor

Страница 1: ...eck the safety devices 3 1 9 Application 4 1 10 Installation 4 1 11 Start up 5 1 12 Maintenance 6 1 13 Repair 7 1 14 Trouble shooting 7 1 15 Technical characteristics 7 1 16 Accessory 8 1 17 Disposal...

Страница 2: ...s when installing the products into the machine as well as information and references for transport storage and maintenance Only in strict compliance with these operating instructions accidents and pr...

Страница 3: ...with the product wear protective gloves For works at and with the product wear safety shoes 1 7 Safety devices The below safety devices are for the safety of the operators As a matter of principle no...

Страница 4: ...ich special guidelines apply especially in stallations and machines For the use at fun fairs and in leisure parks In food processing or special hygiene regulations For military purposes In mines In ex...

Страница 5: ...e correctly 1 For fixing of the customer s connecting construction there are 4 bore holes for M10 10 5 mm at the top plate All provided bore holes have to be used 2 Fasten the connecting construction...

Страница 6: ...Cleaning WARNING Danger of injury due to a lifting or lowering movement Do not reach into the stroke area during the lifting or lower ing movement The following cleaning works have to be effected dai...

Страница 7: ...interior lifting jack may only be effected by the ROEMHELD service techni cians 1 14 Trouble shooting CAUTION All work by service personnel only All works only to be effected by ROEMHELD service staff...

Страница 8: ...ngth the inherent stability and solidity with regard to static or dynamic operating stress The products may only be put into operation after it was as sessed that the incomplete machine machine in whi...

Страница 9: ...ontrol only lifting modules with identification letter G are suitable Supply units with synchronization control for 2 3 or 4 lifting modules are available 2 2 Validity of the documentation This docume...

Страница 10: ...Injuries material damages or malfunctions Do not modify the product Injury burning due to contact with energized parts Before working on electric equipment the energized parts must be de energized an...

Страница 11: ...ngs to possible uses Max pressure load only within the lifting force indicated below technical characteristics Position of the gravity centre of the load within the top plate Use only within closed lo...

Страница 12: ...ad cap screws ISO 4762 M10 onto the concrete floor or the connecting construction of the customer 4 For this purpose professionally insert into the concrete floor heavy duty dowels e g Fischer part no...

Страница 13: ...ousing of the supply and con trol unit Then the screw of the cable bushing has to be tightened with a torque of 0 4 Nm 2 Correct fixing of the supply unit near the lifting module 2 11 1 Operation WARN...

Страница 14: ...fore cleaning switch off power supply Visual check of the lifting module Check the guide unit for damages and possible running marks repair if required 2 12 5 Half yearly checks WARNING Injury due to...

Страница 15: ...915 06 XX E 6000 7 5 7 5 Variante G suitable for synchronization Type Lifting force N vH mm s I A 8915 02 XX G 2000 18 16 6 8915 04 XX G 4000 8 6 4 5 8915 06 XX G 6000 6 4 5 5 vH Lifting speed load de...

Страница 16: ...0 G 60 G 8915 06 20 G 30 G 40 G 50 G 60 G The indicated products have been designed and manufactured in compliance with CE directive 2004 108 CE EMC directive directive on electromagnetic compatibilit...

Страница 17: ...neric standards Immunity for industrial envi ronment DIN EN 61000 6 4 2007 09 Electromagnetic compatibility EMC Generic standards Immunity for industrial environ ment Responsible person for the docume...

Страница 18: ...conformity 17 Electro mechanical version 9 F Fixing of the product 5 13 G General safety tips 2 10 11 I Installation 5 13 Intended use 4 12 L Lifting and lowering 15 List of the applied standards 9 1...

Отзывы: