Operating instructions
BA_M4301_EN
5 / 18
CAUTION
Stroke module, pump lever not operate on bottom base
plate
Foot pedal is pressed down below the lower edge of the base
plate.
•
The customer has to make sure that this will be prevented
by the concrete floor or a corresponding base plate con-
necting construction.
1.
Install the product so that for the required cleaning and
maintenance works there is all around a clearance zone of
at least 700 mm.
2.
The product has to be mounted horizontally on a plane and
solid concrete floor (concrete strength grade B 25) or a rigid
connecting construction of the customer (flatness 0.20 mm).
3.
Fasten the bottom plate of the product with hexagon socket
head cap screws ISO 4762 - M10 onto the concrete floor or
the connecting construction of the customer.
4.
For this purpose professionally insert into the concrete floor
heavy-duty dowels (e.g. Fischer part-no.: SL M-10 N).
Figure 3: principle of fixing
1
Concrete floor or con-
necting construction
2 Foot pedal
3
Bottom plate
4
Top plate
1.10.3
Mounting of the customer's connecting construc-
tion
WARNING
Injury due to overturning product!
•
Overturning product due to eccentric load provided by the
user!
•
The centre of gravity of the user's load must be within the 4
fixing screws of the bottom plate.
•
When introducing torques within the load limit (see technical
characteristics) we recommend to use an additional base
plate (accessory) and to secure this plate correctly.
1.
For fixing of the customer's connecting construction there
are 4 bore holes (for M10 -
∅
10.5 mm ) at the top plate.
All provided bore holes have to be used!
2.
Fasten the connecting construction at the top plate.
Note
Dangers due to the connecting construction of the cus-
tomer
Dangers due to the connecting construction of the customer, as
e.g. squeezing points have to be excluded by the customer's
design.
1.11
Start up
WARNING
Poisoning due to contact with hydraulic oil!
Wear, damage of the seals, ageing and incorrect mounting of
the seal kit by the operator can lead to escapes of oil.
Incorrect connection can lead to escapes of oil at the ports.
•
For handling with hydraulic oil consider the material safety
data sheet.
•
Wear protection equipment.
1.
Check tight seat (check tightening torque of the fixing
screws).
1.11.1
Operation
WARNING
Injuries due to non-compliance of the operating instruc-
tions!
•
The product may only be operated, if the operating instruc-
tions - especially the chapter "Safety instructions" have
been read and understood.
Injury by crushing!
Components of the product make a movement while they are in
operation.
•
This can cause injuries.
•
Keep parts of the body and items out of the working area!
Injuries due to misuse, incorrect operation or abuse!
Injuries can occur if the product is not used within the intended
use and the technical performance data.
•
Before start up, read the operating instructions!
The operator is obliged to report immediately any changes at
the product that may affect the safety to the safety expert or to
the person who is responsible for safety and to stop operating
the product.
2
1
3
4