background image

 

Operating instructions 

BA_M4301_EN 

 

 

 

16 / 18 

 

 

 

Figure 13: Lifting module with incremental measuring system 
(8915-0X-X0-G) 

6  red = pulse generator 

3

 

brown  

 

+ (extend) 

 

- (retract) 

1  yellow = COM 

4  blue 
 

- (extend) 

 

+ (retract) 

5  black = limit switch 

 

 

2.16 

Accessory 

 

 

Base plate for increased stability, data sheet M8100 

Part-no. 

6311-412 

 

Electrical accessories, data sheet M8200 

Foot switch 

3823-038 

Hand panel 

3823-025 

Supply unit for 1 lifting mod-
ule 

3821-246 

Mains cable smooth 

3823-040 

 

Further accessory 

M8110, M8130, M8131, 

 

 

2.17 

Disposal 

 

The individual materials have to be disposed as per the existing 
regulations and directives as well as the environmental condi-
tions. 
For the disposal of electrical and electronic components (e.g. 
stroke measuring systems, proximity switches, etc.) country-
specific legal regulations and specifications have to be kept. 
 

 

 

 

Hazardous to the environment 

Due to possible environmental pollution, the indi- 
vidual components must be disposed only by an 
authorised expert company. 

 

 

 

 

2.18 

EC-Declaration of conformity 

 

Manufacturer 
Römheld GmbH Friedrichshütte  
Römheldstraße 1-5 
35321 Laubach, Germany 
Tel.: +49 (0) 64 05 / 89-0 
Fax: +49 (0) 64 05 / 89-211 
E-mail: [email protected] 
www.roemheld.com 
 

 

2.18.1 

Validity of the documentation 

 

This document applies to the following products: 

 

Electro-mechanical lifting modules of data sheet M 4.301.  
The following types or part numbers are concerned: 
• 

8915-01-20-E,  -30-E, -40-E, -50-E, -60-E 

• 

8915-02-20-E,  -30-E, -40-E, -50-E, -60-E 

• 

8915-04-20-E,  -30-E, -40-E, -50-E, -60-E 

• 

8915-06-20-E,  -30-E, -40-E, -50-E, -60-E 

 
• 

8915-02-20-G,  -30-G, -40-G, -50-G, -60-G 

• 

8915-04-20-G,  -30-G, -40-G, -50-G, -60-G 

• 

8915-06-20-G,  -30-G, -40-G, -50-G, -60-G 

 

 

The indicated products have been designed and manufactured 
in compliance with CE directive 2004/108/CE – EMC directive 
(directive on electromagnetic compatibility) according to their 
current version and the additionally applicable technical rules.  
According to EG MSRL and EN 982, these products are com-
ponents which are not ready for use and exclusively intended 
for installation in an incomplete machine / machine.  
 
The products must not be put in operation, before it has been 
verified that the incomplete machine / machine into which the 
products are to be installed complies with the provisions of the 
machinery directive (2006/42/CE). 
 
The manufacturer is obliged to provide the relevant documenta-
tion for the products to state agencies upon request.  
The technical documentation for the products as per Annex IV 
has been prepared. 
 

 

2.18.2 

List of the applied standards 

2006/42/EC Machinery Directive 

 

2002/95/EC, Directive on the restriction of the use of certain 
hazardous substances in electrical and electronic equipment 
(RoHS) 

 

DIN EN 349, 2008-09, Safety of machinery. Minimum gaps to 

avoid crushing of parts of the human body 

 

DIN EN 1494; 2009-05,

 

Mobile or movable jacks and associ-

ated lifting equipment 

 

DIN EN ISO 12100, 2011-03, Safety of machinery; Basic con-

cepts, General principles for design (replacement for part 1 
and 2) 

 

DIN EN ISO 14121-1, 2007-12, Safety of machinery- Risk as-

sessment- Part 1: Principles 

 

DIN EN 60529; 2000-09, Degrees of protection provided by 

enclosures (IP- Codes) 

 

DIN EN 60204-1; 2007-06, Safety of machinery - Electrical 

equipment of machines, Part 1: General requirements 

 

DIN EN 60309; 2007-11,

 

VDE 0623-1:2007-11, Plugs, socket-

outlets and couplers for industrial purposes – Part 1: Gen-
eral requirements 

 

Содержание Shop-Floor

Страница 1: ...eck the safety devices 3 1 9 Application 4 1 10 Installation 4 1 11 Start up 5 1 12 Maintenance 6 1 13 Repair 7 1 14 Trouble shooting 7 1 15 Technical characteristics 7 1 16 Accessory 8 1 17 Disposal...

Страница 2: ...s when installing the products into the machine as well as information and references for transport storage and maintenance Only in strict compliance with these operating instructions accidents and pr...

Страница 3: ...with the product wear protective gloves For works at and with the product wear safety shoes 1 7 Safety devices The below safety devices are for the safety of the operators As a matter of principle no...

Страница 4: ...ich special guidelines apply especially in stallations and machines For the use at fun fairs and in leisure parks In food processing or special hygiene regulations For military purposes In mines In ex...

Страница 5: ...e correctly 1 For fixing of the customer s connecting construction there are 4 bore holes for M10 10 5 mm at the top plate All provided bore holes have to be used 2 Fasten the connecting construction...

Страница 6: ...Cleaning WARNING Danger of injury due to a lifting or lowering movement Do not reach into the stroke area during the lifting or lower ing movement The following cleaning works have to be effected dai...

Страница 7: ...interior lifting jack may only be effected by the ROEMHELD service techni cians 1 14 Trouble shooting CAUTION All work by service personnel only All works only to be effected by ROEMHELD service staff...

Страница 8: ...ngth the inherent stability and solidity with regard to static or dynamic operating stress The products may only be put into operation after it was as sessed that the incomplete machine machine in whi...

Страница 9: ...ontrol only lifting modules with identification letter G are suitable Supply units with synchronization control for 2 3 or 4 lifting modules are available 2 2 Validity of the documentation This docume...

Страница 10: ...Injuries material damages or malfunctions Do not modify the product Injury burning due to contact with energized parts Before working on electric equipment the energized parts must be de energized an...

Страница 11: ...ngs to possible uses Max pressure load only within the lifting force indicated below technical characteristics Position of the gravity centre of the load within the top plate Use only within closed lo...

Страница 12: ...ad cap screws ISO 4762 M10 onto the concrete floor or the connecting construction of the customer 4 For this purpose professionally insert into the concrete floor heavy duty dowels e g Fischer part no...

Страница 13: ...ousing of the supply and con trol unit Then the screw of the cable bushing has to be tightened with a torque of 0 4 Nm 2 Correct fixing of the supply unit near the lifting module 2 11 1 Operation WARN...

Страница 14: ...fore cleaning switch off power supply Visual check of the lifting module Check the guide unit for damages and possible running marks repair if required 2 12 5 Half yearly checks WARNING Injury due to...

Страница 15: ...915 06 XX E 6000 7 5 7 5 Variante G suitable for synchronization Type Lifting force N vH mm s I A 8915 02 XX G 2000 18 16 6 8915 04 XX G 4000 8 6 4 5 8915 06 XX G 6000 6 4 5 5 vH Lifting speed load de...

Страница 16: ...0 G 60 G 8915 06 20 G 30 G 40 G 50 G 60 G The indicated products have been designed and manufactured in compliance with CE directive 2004 108 CE EMC directive directive on electromagnetic compatibilit...

Страница 17: ...neric standards Immunity for industrial envi ronment DIN EN 61000 6 4 2007 09 Electromagnetic compatibility EMC Generic standards Immunity for industrial environ ment Responsible person for the docume...

Страница 18: ...conformity 17 Electro mechanical version 9 F Fixing of the product 5 13 G General safety tips 2 10 11 I Installation 5 13 Intended use 4 12 L Lifting and lowering 15 List of the applied standards 9 1...

Отзывы: