The second digit represents the alarm type for panic or tamper zone
and the alarm type as well when [*] and [#] keys are pressed simulta-
neously (see section 09).
S
ECTION
[11] - S
YSTEM
T
IMES
Enter 3 groups of 3 digits each (001 to 255 seconds), to establish the three
system delays:
Entry Delay
The Entry Delay determines the lapse of time allowed between the activation
of an
Entry/Exit
zone and system disarming. If the system is not disarmed
during this delay, an alarm will be generated. The default Entry Delay is 30
seconds.
Exit Delay
The Exit Delay determines the lapse of time allowed between entering an
access code to arm the system, and the activation of an
Entry/Exit
zone to
exit the protected area. The default Exit Delay is 120 seconds.
Bell cut-off time
The bell cut-off time represents how long the siren will be enabled when an
alarm occurs. When an alarm occurs, the siren will sound until this period of
time is exceeded or an access code is entered.
Example:
These times are to be programed this way:
Entry time - 10 seconds
Exit time - 60 seconds
Bell cut-off time - 3 minutes
After entering the section by pressing [1][1], enter the sequence:
[0][1][0] [0][6][0] [0][0][3]
After each of the 3 digits, the keypad buzzer will sound 3 beeps. After
entering the last 3 digits, the keypad buzzer will sound 6 beeps and exit the
section 11 waiting for a new command.
S
ECTION
[12] I
NSTALLER
'
S
C
ODE
C
HANGING
The default value for the Installer's Code is [0269]. It is strongly recom-
mended to change this code after completing the installation of the alarm
system. Keep the new code in a safe place.
Enter 4 digits [X] [X] [X] [X]. Next, the keypad buzzer will sound 6 beeps and
will exit section 12 waiting for a new command.