Installation

Ensure that at the installation location a power plug in available nearby. For the wall 
installation you can use the screws delivered with the unit.
It is very important that the Helpy GSM unit has all time the best GSM signal to 
avoid disturbances during operation time. Before you install the device at his fi nal 
position be sure that it is the best spot you can fi nd. To do this use an mobile phone 
with a SIM card of the same provider that you are going to use with the Helpy GSM 
and try at the spot you are going to use to setup a communication. If during the 
conversation you will notice disturbances or interruptions you will have to look for a 
better position.

SIM card installation

For the installation of the SIM card be sure that the devices is 

SWITCHED OFF

! The 

SIM card has to be placed into the specifi c slot. The card should have the PIN code 
disabled.

PLEASE NOTE!
If you change the SIM card switch all time the POWER OFF!

Ensure that the PIN code of the SIM card is disabled with a mobile phone BE-
FORE you install it into the device.

If the SIM card is changed ensure that the new card has the PIN code is 
disabled. 

For a proper maintenance of the device you need a SIM card with SMS and 
GPRS data volume. SMS is required for programming and data volume for fi rm-
ware updates. For data connectivity ensure that you have the APN user name 
and password available from your provider.

GSM antenna

The antenna provided is connected to the device with the proper connector outside 
the case. If you notice problems in getting a proper GSM network signal you may 
change the antenna. Specifi c antennas may solve the problem. Ask the technical 
support for more informations,

PLEASE NOTE!
Never power the Helpy GSM WITHOUT connected antenna. The radio transmis-
sion engine may be damaged.

The device is designed for statical installation and external power supply with 230 
VAC. If required also a 12 VDC (min 11, max. 15 VDC) power voltage can be used. 
The device has an internal NiMH battery for emergency power supply if external 
power is missing.

Connection of the external power supply

Содержание HELPY GSM

Страница 1: ...Quick user guide Helpy GSM Issue 1 00 Page 1 Quick user guide HELPY GSM EN81 28 2018 integrated GSM lift emergency call system...

Страница 2: ...the identi cation message 13 ID code programming 14 Check the programmed ID code 14 Test call 15 Check test call programming 15 Test alarms 15 Acknowledgement procedure 16 Check acknowledgement proce...

Страница 3: ...ESSETI P100 26 Alarm call to a normal phone DTMF 26 Driver contact 27 Ending the alarm 28 Optical indicators 29 Green LED for GSM signal strength 29 Red LED for device status 29 Yellow LED for alarm...

Страница 4: ...r local telephone M Battery compartment door N Terminal blocks O Built in microphone Installation place The installation place for the device must be inside a dry room free from dust heat and direct s...

Страница 5: ...use of GSM device in an airplan is forbidden by law Use within an hospital Switch Helpy GSM off if you are close to any electromedical apparature Please take care that disturbances may affect the use...

Страница 6: ...all time the POWER OFF Ensure that the PIN code of the SIM card is disabled with a mobile phone BE FORE you install it into the device If the SIM card is changed ensure that the new card has the PIN c...

Страница 7: ...t to ash quickly In this case the SIM card has to be changed If everything is OK the device will start the initialisation procedure and login to the provider This can take some time about 30 to 60 sec...

Страница 8: ...LOUDSPEAKER OF A PASSIVE SPEAKER UNIT MIC2 INPUT FOR CONNECTING THE MICROPHONE OF A PASSIVE SPEAKER UNIT OR A SINGLE MICROPHONE MIC3 INPUT FOR CONNECTING THE MICROPHONE OF A PASSIVE SPEAKER UNIT OR A...

Страница 9: ...cting the emergency call button Powerless button with plain contact Existing button Siren Negative pole 12 to 24 Vdc Helpy GSM connecting an powerless alarm button normal closed or normal open Helpy G...

Страница 10: ...ge 10 General wiring diagram Helpy GSM general wiring diagram HELPY GSM cabin top or machine room Machine room intercom Lift cabin Pictogram yellow Pictogram green Emergency button Microphone or passi...

Страница 11: ...allowed After this time you get a warn tone and you must hang up This quick guide is only a short description of the most important programma tions The complete overview can only be found in the Esta...

Страница 12: ...battery alarm 3 for test call 5 for SIM card expiring alarm 6 for diagnostic alarm microphone loudspeaker failure 7 for power failure 8 for general technical alarm 9 for end of alarm protocol can hav...

Страница 13: ...hg password default 0 position Recording identi cation message Check the programmed telephon numbers If an emergency or technical alarm call is sent to a normal phone instead of a proper call center y...

Страница 14: ...code always 8 digits long SMS Et hg password default 0 222 ESSETI ID code always 10 digits long Et hg password default 0 222 P100 ID code always 8 digits long Example You want to program a Sie P100 ID...

Страница 15: ...9 Example You to send a test call every day at 2 00 am DTMF 311 320200 SMS with default password Et hg 0 311 320200 PLEASE NOTE The test call is activated only after you have programmed a proper telep...

Страница 16: ...he con trary to pure analogue solutions the emergency phone knows always when the called party will answer and close the call In this way it is possible to manage an emergency call to more telephone n...

Страница 17: ...ttings by dialing DTMF 77 SMS Et hg password default 0 77 Speech connection You can de ne when a speech connection must be established microphone activati on after a call answer Only after sending the...

Страница 18: ...2 seconds Emergency alarm call is active Emergency call button is pressed siren driver GSM network failure default As default the relay is used to signal a GSM network failure i e to switch off the l...

Страница 19: ...has been answered Et hg password default 0 7512 Power failure after 30 seconds Et hg password default 0 7513 Driver contact activation time 2 seconds Et hg password default 0 7514 mergency alarm call...

Страница 20: ...password default 0 42 Filtering time for emergency call button 2 to 9 seconds Time setting To ensure that the test call will be send at the required hour the real time clock inside the device must be...

Страница 21: ...ting by dialing DTMF 35 SMS Et hg password default 0 35 Date setting To ensure that the clock will switch between summer and winter time as well that the log entries have the right date the actual dat...

Страница 22: ...d default 0 801 loudspeaker 1 5 microphone 8 9 Ansagen Et hg password default 0 804 messages 1 5 Example You want to change the volume for the messages from 2 to 5 DTMF 8045 SMS Et hg password default...

Страница 23: ...ord max 5 digits SMS Et hg password default 0 92 old password new password max 5 digits new password max 5 digits Example You want to change the password from 0 to 1234 DTMF 920 1234 1234 SMS Et hg pa...

Страница 24: ...nguage third message language SMS Et hg password default 0 89 second message language third message language Where second third message language can have the following value 00 for italian 01 for engl...

Страница 25: ...le to set all required programming values and store them thne on a SD micro memory card This data can then be trans fered to the emergency phone To do this inserte the card in the proper slot and dial...

Страница 26: ...sing the key 4 The speech connection will be activated 2 After the call answer and the message advising the emergency call an identi cati on message will be played With the key 1 you can let play this...

Страница 27: ...ncy phone PLEASE NOTE The described procedur refer to the the standard DTMF code provided as de fault As this codes can be programmed so that the device could use different codes Helpy GSM DTMF emerge...

Страница 28: ...as defalut and must be programmed see also acknowledgement procedure If the end of alarm is set for local termination it can be ended after liberation dia ling From the machine room phone Lift the han...

Страница 29: ...Good signal Average signal Week signal A connection is active Device is NOT logged in the GSM network Device is logged in the GSM network A alarm call has been sent Technical test call alarm active A...

Страница 30: ...rogramming using DTMF SMS PC SD card Abmessungen HxBxT 60 x 165 x 125 mm Gewicht 655 g with battery Operating temperature 0 to 40 C Humidity 30 to 90 relative humidity without condensing Case ABS GSM...

Страница 31: ...Quick user guide Helpy GSM Issue 1 00 Page 31 Your notes...

Страница 32: ...ssysteme GmbH Lessing Str 20 63110 Rodgau Germany Tel 49 0 6106 6600 0 Fax 49 0 6106 6600 66 E Mail info rocom gmbh de http www rocom gmbh de 29 7006 0010 Ver 1 00 2021 ROCOM GmbH We do not take any r...

Отзывы: