To order parts and supplies: 800.343.9353 >> eastwood.com
7
Tool Doesn’t
Respond
to Trigger
Depression
Insufficient
Volume of
Air (CFM) to
Operate Tool
Verify sufficient air supply to tool
(6 CFM @ 90 PSI minimum requirement).
Moisture
or Other
Contamination
in Air Supply
Check for moisture in air line and tool air inlet.
Tool
Performance
is Slow of
Sluggish
Insufficient
Volume of
Air (CFM) to
Operate Tool
Verify sufficient air supply to tool
(6 CFM @ 90 PSI minimum requirement).
Moisture
or Other
Contamination
in Air Supply
Check for moisture in air line and tool air inlet.
Air Motor
is Lacking
Lubrication
Stop use immediately and add air tool oil directly
to air inlet.
Tool is
Excessively
Noisy/Emits
High Pitched
Sound
Air Motor
is Lacking
Lubrication
Stop use immediately and add air tool oil directly
to air inlet.
Tool Vibrates
Excessively
During Use
Out of Balance
Condition from
Damaged
Grinding Wheel
Stop use immediately, check for damage and
replace Grinding Wheel.
Loose Spindle
Nut
Tighten loose Spindle Nut.
TROUBLESHOOTING