Programming and Parameters
2-27
UTILITY
Diagnostics
230
[Alarm 2 @ Fault]
Captures and displays [Drive Alarm 2] at the time of
the last fault.
Note: Bits 14 and 15 were added for firmware
version 2.001.
Read Only
thru
Fa
u
lt
s
238
[Fault Config 1]
Enables/disables annunciation of the listed faults.
Notes: Bit 9 “Load Loss” should not be changed from “0”. Bit 10 was added for
firmware version 2.001. Bits 2 “Motor Stall” and 11 “Shear PNO Ac” were added
for firmware version 3.001.
240
[Fault Clear]
Resets a fault and clears the fault queue.
Default:
Options:
0
0
1
2
“Ready”
“Ready”
“Clear Faults”
“Clr Flt Que”
241
[Fault Clear Mode]
Enables/disables a fault reset (clear
faults) attempt from any source. This does
not apply to fault codes which are cleared
indirectly via other actions.
Default:
Options:
1
0
1
“Enabled”
“Disabled”
“Enabled”
242
[Power Up Marker]
Elapsed hours since initial drive power up.
This value will rollover to 0 after the drive
has been powered on for more than the
max value shown. For relevance to most
recent power up see [Fault x Time].
Default:
Min/Max:
Units:
Read Only
0.0000/429496.7295 Hr
0.1 Hr
244
246
248
250
252
254
256
258
243
245
247
249
251
253
255
257
[Fault 1 Code]
[Fault 2 Code]
[Fault 3 Code]
[Fault 4 Code]
[Fault 5 Code]
[Fault 6 Code]
[Fault 7 Code]
[Fault 8 Code]
A code that represents the fault that
tripped the drive. The codes will appear in
these parameters in the order they occur
([Fault 1 Code] = the most recent fault).
Default:
Min/Max:
Units:
Read Only
0/65535
0
File
Gr
oup
No.
Parameter Name & Description
Values
Related
0
0
0
0
0
0
0
0
x
0
0
0
10
0
1
2
3
4
5
6
7
8
9
11
12
13
14
15
1
= Condition True
0
= Condition False
x = Reserved
Bit #
DigIn T
est
DigIn CflctB
DigIn CflctC
Bipolr Cflct
MtrT
yp Cflct
NP Hz Cflct
MaxFr
q Cflct
VHz NegSlope
SpdRef Cflct
Sleep Config
TB Ref Cflct
Reser
ved
PTC Cflct
HD
W OverT
emp
x
x
0
0
Reser
ved
Reser
ved
1
0
0
0
0
0
1
0
0
x
x
x
x
10
0
1
2
3
4
5
6
7
8
9
11
12
13
14
15
1
= Enabled
0
= Disabled
x = Reserved
Bit #
Factory Default Bit Values
Po
w
er Loss
UnderV
olta
ge
Motor Overld
A
utRst T
ries
Decel Inhib
Motor Therm
Phase Loss
Load Loss
Shear Pin
Gate Disab
le
0
0
Shear PNO Ac
1
Motor Stall
Содержание powerflex 700h
Страница 1: ...PROGRAMMING MANUAL High Power Firmware Versions x xxx 3 001 PowerFlex 700H AC Drives ...
Страница 10: ...P 4 Overview Notes ...
Страница 56: ...2 42 Programming and Parameters Notes ...
Страница 70: ...3 14 Troubleshooting Notes ...
Страница 103: ......