6
Rockwell Automation Publication 6300B-IN001C-EN-P - February 2021
VersaView 6300B Box PCs and 6300T Box Thin Clients Installation Instructions
For 6300B-BMFx and 6300B-DRFx Box PCs
To assemble and attach the connector assembly, perform the following steps.
1.
Remove the DC terminal block from the computer chassis.
2.
Strip 10 mm (0.4 in.) from the end of four different-colored wires.
3.
Press the spring connection tabs on the DC terminal block, and insert each
stripped end of wire according to the following table.
4.
Release the spring connection tabs after the stripped end of each wire has been
fully inserted in the appropriate terminal connection.
5.
Reconnect the DC terminal block to the computer chassis.
Torque the DC terminal block flange screws to 0.3 N•m (0.22 ft•lb).
6.
Proceed to
.
Connect DC Power
All VersaView DC powered models require a safety extra low voltage (SELV) power supply. The internal power supply is protected against reverse polarity.
To minimize ground loop currents and noise, Allen-Bradley® recommends that DC powered models use only one grounded connection. See
Install the Ground Wire on page 4
for the
ground connection on these models.
Computer Light-emitting Diode and Button Descriptions
Once power is supplied to the computer, light-emitting diodes (LEDs) signify the following.
IMPORTANT
Use stranded copper wire sized 1.5 mm
2
(16 AWG)
and certified for at least 85 °C operation.
ATTENTION:
When you connect power to the box PC or box thin client for the first time, these actions occur:
• The default UEFI setting automatically starts the computer after it is plugged into a power source.
• For VersaView 6300B box PCs with a Microsoft Windows® operating system (OS), you must read and accept an End User Setup procedure.
Do not disconnect power from the system until after the Windows Setup procedure is completed. If power is disconnected during this
procedure, it can result in a corrupted system image.
Table 1 - LEDs and Buttons on the Front Panel of VersaView 6300B-BMA
x
, 6300B-BMF
x
, and 6300B-DRF
x
Box PCs, and VersaView 6300T-BA
x
1 Box Thin Clients
No.
Description
Color
Power Status
1
Standby/power on LED
No color
The computer is powered off.
Green
The computer is powered on.
Yellow
The computer is safe to power off; the operating system has been shut down
successfully
(1)
.
(1)
Microsoft Windows operating systems are not installed on VersaView 6300T thin client models.
Flashing green The computer is in a low-power state; the current session information is being stored in its
RAM.
2
Mass storage LED
Yellow
When lit, access to a mass storage device (SSD or CF) is happening through a SATA
channel.
3
Watchdog LED
Green
The watchdog is working.
Red
The watchdog timer has expired.
4
Thermal alarm/
low battery LED
Red
A thermal sensor on the motherboard near the CPU has exceeded the thermal limit of
85 °C (185 °F).
Flashing red
The clock battery power is below 2.5V; consider replacing. At 2V, data and time loss is
possible.
5
Power/system reset button
—
For the main reset of the system. Press this button once to restart the computer and reset
the system state.
6
Watchdog reset button
—
Press this button once to reset the watchdog error LED.
Item
Abbreviation
Function
1
+
+ Input voltage (fused)
2
—
- Input voltage
3
SYS OFF
System OFF input
4
PS
Power status output (0.5 A limited)
3
2
1
4
1
2
3
4
1
2
3
4
5
6