To assemble and attach the connector assembly, perform the following steps.

1.

Remove the DC terminal block from the computer chassis.

2.

Strip 10 mm (0.4 in.) from the end of four different-colored wires.

3.

Press the spring connection tabs on the DC terminal block, and insert each 

stripped end of wire according to the following table.

4.

Release the spring connection tabs after the stripped end of each wire has been 

fully inserted in the appropriate terminal connection.

5.

Reconnect the DC terminal block to the computer chassis. 
Torque the DC terminal block flange screws to 0.3 N•m (0.22 ft•lb).

6.

Proceed to 

Connect DC Power

.

Connect DC Power

All VersaView DC powered models require a safety extra low voltage (SELV) power supply. The internal power supply is protected against reverse polarity.
To minimize ground loop currents and noise, Allen-Bradley® recommends that DC powered models use only one grounded connection. See 

Install the Ground Wire on page 4

 for the 

ground connection on these models.

Computer Light-emitting Diode and Button Descriptions

Once power is supplied to the computer, light-emitting diodes (LEDs) signify the following.

IMPORTANT

Use stranded copper wire sized 1.5 mm

2

 (16 AWG) 

and certified for at least 85 °C operation.

ATTENTION: 

When you connect power to the box PC or box thin client for the first time, these actions occur:

• The default UEFI setting automatically starts the computer after it is plugged into a power source.
• For VersaView 6300B box PCs with a Microsoft Windows® operating system (OS), you must read and accept an End User Setup procedure.

Do not disconnect power from the system until after the Windows Setup procedure is completed. If power is disconnected during this 

procedure, it can result in a corrupted system image.

Table 1 - LEDs and Buttons on the Front Panel of VersaView 6300B-BMA

x

, 6300B-BMF

x

, and 6300B-DRF

x

 Box PCs, and VersaView 6300T-BA

x

1 Box Thin Clients 

No.

Description

Color

Power Status

1

Standby/power  on  LED

No color

The computer is powered off.

Green

The computer is powered on.

Yellow

The computer is safe to power off; the operating system has been shut down 

successfully

(1)

.

(1)

Microsoft Windows operating systems are not installed on VersaView 6300T thin client models.

Flashing green The computer is in a low-power state; the current session information is being stored in its 

RAM.

2

Mass storage LED

Yellow

When lit, access to a mass storage device (SSD or CF) is happening through a SATA 

channel.

3

Watchdog  LED

Green

The watchdog is working.

Red

The watchdog timer has expired.

4

Thermal alarm/

low battery LED

Red

A thermal sensor on the motherboard near the CPU has exceeded the thermal limit of 

85 °C (185 °F).

Flashing red

The clock battery power is below 2.5V; consider replacing. At 2V, data and time loss is 

possible.

5

Power/system reset button

For the main reset of the system. Press this button once to restart the computer and reset 

the system state.

6

Watchdog reset button

Press this button once to reset the watchdog error LED.

Item

Abbreviation

Function

1

+

+ Input voltage (fused)

2

-  Input  voltage

3

SYS  OFF

System  OFF  input

4

PS

Power status output (0.5 A limited)

3

2

1

4

1

2

3

4

1

2

3

4

5

6

Содержание Allen-Bradley VersaView 6300B

Страница 1: ...ing to the Connect Peripherals section The picture for 6300B BMFx and 6300B DRFx models The digital input output I O item to the picture and table The USB cable length stipulation 4 Changed the heading from Connect DC Power to Connect DC Power Wiring 4 Added the subheading For 6300B BMAx and 6300B BMBx Box PCs and 6300T BAx1 Box Thin Clients to the Install the DC Connector Assembly section 5 Added...

Страница 2: ... at the bottom as shown in Figure 1 on page 3 Mount the box PC or box thin client so there is at least 20 mm 0 8 in of clearance on each side for the circulation necessary for cooling Required Tools and Hardware for Installation The following tools are needed for the mounting bracket installations A drill and 4 mm drill bit 2 Phillips screwdriver Four M4x20 stainless steel screws customer supplied...

Страница 3: ...0 75 230 9 06 19 0 75 6 0 24 4 x Ø 4 1 8 25 0 98 25 0 98 100 3 97 150 5 9 5 5 0 22 100 3 97 150 5 9 256 5 10 1 268 10 6 Front View Vertical Upright Position Side View 6300B BMAx Box PCs and 6300T BAx1 Box Thin Clients 6300B BMBx Box PCs 221 8 7 6300B BMFx Box PCs 47 1 85 4 5 0 18 127 25 5 01 140 5 51 20 0 79 100 3 94 8 25 0 32 77 3 03 100 3 94 20 0 79 4 x Ø 4 5 0 18 Front View Vertical Upright Pos...

Страница 4: ...wer Wiring Follow these steps to connect the box PC or box thin client to a DC power source Install the Ground Wire 1 Turn off the main power switch or breaker 2 Remove the supplied nut eyelet terminal and washers from the ground screw 3 For earth ground fasten a 2 5 mm2 14 AWG or larger external wire to the eyelet terminal Use a ground wire with an insulation color that is approved by local inspe...

Страница 5: ...es 9 Use cutting pliers to cut the excess part of the cable tie D 10 Install the white label supplied with the kit E 11 Align and install the other connector clamp half to complete the assembly F 12 Reconnect the DC terminal block with the connector assembly to the computer chassis Torque the DC terminal block flange screws to the values in Figure 2 13 Proceed to Connect DC Power on page 6 IMPORTA...

Страница 6: ...ally starts the computer after it is plugged into a power source For VersaView 6300B box PCs with a Microsoft Windows operating system OS you must read and accept an End User Setup procedure Do not disconnect power from the system until after the Windows Setup procedure is completed If power is disconnected during this procedure it can result in a corrupted system image Table 1 LEDs and Buttons on...

Страница 7: ...ate and time 5 Watchdog LED Green The watchdog is working Red The watchdog timer has expired 6 PLC status LED 2 7 BUS status LED 2 8 Power on reset button Turns the computer on or off 9 System reset button Forces an internal reset as if power was lost temporarily and then returned IMPORTANT Use this button only if there are no better options like keyboard or mouse commands System reset can cause d...

Страница 8: ...on its website at rok auto pec Your comments help us serve your documentation needs better If you have any suggestions on how to improve our content complete the form at rok auto docfeedback For technical support visit rok auto support Rockwell Otomasyon Ticaret A Ş Kar Plaza İş Merkezi E Blok Kat 6 34752 İçerenkÖy İstanbul Tel 90 216 5698400 EEE YÖnetmeliğine Uygundur This computer contains a sea...

Отзывы: