90
Rockwell Automation Publication 20Y-TG002C-EN-P - April 2017
Chapter 7
LCL Filter Component Section
Figure 13 - Remove Input Bus Bar Connections
8. See
, Detail D and remove the 12 M6 x16 screws that secure
the LCL filter output bus bars to the AFE power structure.
9. See
and slide the LCL filter out of the enclosure.
From the IP21 Rittal Enclosure
To remove the LCL filter from an IP21 Rittal enclosure, follow these steps.
1. Remove power from the AFE.
Remove Power from the AFE on page 37
.
2. Remove the LCL filter protective barriers.
Remove the LCL Filter Protective Barriers and Vented Cover on
3. Remove the X51 and X53 terminal blocks from the LCL fan assembly.
ATTENTION:
The LCL filter is heavy. To avoid personal injury or
damage to the equipment, use caution when removing the LCL filter
from the enclosure.
IMPORTANT
Ramps can be required due to enclosure floor mismatch.
DETAIL C
DETAIL D
Содержание Allen-Bradley PowerFlex 700AFE
Страница 10: ...10 Rockwell Automation Publication 20Y TG002C EN P April 2017 Preface Notes ...
Страница 18: ...18 Rockwell Automation Publication 20Y TG002C EN P April 2017 Chapter 1 Troubleshooting and Error Codes Notes ...
Страница 26: ...26 Rockwell Automation Publication 20Y TG002C EN P April 2017 Chapter 2 Active Front End System Overview Notes ...
Страница 82: ...82 Rockwell Automation Publication 20Y TG002C EN P April 2017 Chapter 6 Precharge Component Section Notes ...
Страница 92: ...92 Rockwell Automation Publication 20Y TG002C EN P April 2017 Chapter 7 LCL Filter Component Section Notes ...
Страница 96: ...96 Rockwell Automation Publication 20Y TG002C EN P April 2017 Chapter 8 DC Fuses Component Section Notes ...
Страница 100: ...100 Rockwell Automation Publication 20Y TG002C EN P April 2017 Appendix A Service Tools and Equipment Notes ...
Страница 128: ...128 Rockwell Automation Publication 20Y TG002C EN P April 2017 Appendix C Connector Descriptions Notes ...
Страница 143: ......