Chapter
2
Start Up
This chapter describes how you start up the PowerFlex 700 Drive. Refer
to
for a brief description of the LCD HIM (Human Interface
Module).
Before Applying Power to the Drive
❏
1.
Confirm that all inputs are connected to the correct terminals and are
secure.
❏
2.
Verify that AC line power at the disconnect device is within the rated
value of the drive.
❏
3.
Verify that control power voltage is correct.
The remainder of this procedure requires that a HIM be installed. If
an operator interface is not available, remote devices should be used
to start up the drive.
Important:
When power is first applied, the HIM may require
approximately 5 seconds until commands are
recognized (including the Stop key).
For information on . . .
See page . . .
!
ATTENTION:
Power must be applied to the drive to perform the
following start-up procedure. Some of the voltages present are at
incoming line potential. To avoid electric shock hazard or damage to
equipment, only qualified service personnel should perform the
following procedure. Thoroughly read and understand the procedure
before beginning. If an event does not occur while performing this
procedure,
Do Not Proceed
.
Remove Power
including user supplied
control voltages. User supplied voltages may exist even when main AC
power is not applied to then drive. Correct the malfunction before
continuing.
Prepare For Drive Start-Up
Содержание Allen-Bradley PowerFlex 700 B Series
Страница 1: ...Adjustable Frequency AC Drive Series B Firmware Versions 4 001 User Manual www abpowerflex com ...
Страница 10: ...P 6 Overview Notes ...
Страница 36: ...1 26 Installation Wiring Notes ...
Страница 118: ...3 78 Programming and Parameters Notes ...
Страница 162: ...A 28 Supplemental Drive Information Notes ...
Страница 227: ......