Maintenance
Lubrication
Your linear thruster has been lubricated at the factory and is ready for
installation. Use the appropriate lubrication interval shown below for schedule
estimates or use Motion Analyzer software to calculate the recommenced re-
grease schedule for the linear thruster.
Before You Begin
You need the following tools to clean and lubricate your linear stage .
• Grease pump kit (catalog number MPAS-GPUMP) with tip type
installed and primed
• Grease cartridge (catalog number MPAS-CART), included in grease
pump kit.
• Lint free cloth
• Isopropyl alcohol, as necessary for cleaning
Recommended Maintenance Interval
Recommended maintenance and lubrication interval for frame 50, 75, 100,
and 150 linear thrusters is every 6 months or 5000 km of travel, whichever
comes first. Frame 30 linear thrusters are lubricated for life.
Topic
Page
ATTENTION:
Lockout and tagout input power before servicing.
TIP
A grease gun typically delivers one gram of lubricant for one pump of the
gun.