Kinetix MMA Asynchronous Main Motors Installation Instructions
Replace, Inspect, and Maintain Blower Filters
Filter media is made of synthetic fiber and has a corrugated matte to help increase the effectiveness. It must be properly cleaned and maintained to be effective.
Axial Blower Filter
There is no axial filter available. The customer is responsible for any filtering and impacts of airflow that would occur because of an installed blower filter.
Radial Blower Filter
On motors equipped with a filter, periodically inspect, clean, or replace the filter. If a filter is installed, avoid operating a motor without a filter in place. The air filter must
always be kept in good working condition. Dirty air filters affect the performance of the motor and may cause overheating and the intervention of the thermal switches.
A clogged air filter is directly related to the degree of impurity of the intake air, and so it is not possible to say what the average time between inspections and cleanings is.
Normally, conduct cleaning about every 200 working hours, however, there are cases when the work is required more frequently.
Radial blower filters must be inspected, cleaned, and replaced regularly. Air
filters are not provided as a replacement part from Rockwell Automation. Use
the information in
to source a filter. To replace a radial blower filter,
follow these instructions:
1.
Remove power from the motor and de-energize the system.
2.
Loosen the screws that secure the filter to the blower air inlet.
3.
Slide the filter out.
4.
Clean or replace the filter. See
• Blow out filter.
When blowing out the filter, apply compressed air from the
internal surface of the filter outward, being careful not to blow the
dirt inside the motor. See
• Replace filter. See
for filter dimensions.
5.
Reinstall filter.
6.
Insert and hand-tighten the screws that secure the filter.
Table 50 - Radial Blower with 3-PH Input Voltage
Motor Cat. No.
Power Supply (V AC)/Hz
Max Current (A)
Power (kW)
Max Airflow
(m
3
/min)
Max Pressure (Pa)
Blower Kit
(1)
(1)
The ‘2B’ indicates that the blower kit fits both a brake and non-brake configuration, MM-BLWR-
xxx
-
2B
-x.
MMA-B132
xxx
3-PH; 380…420V AC; 50 Hz /
440…480V AC; 60 Hz
0.75
0.25
15
800
MM-BLWR-132-2B-C
MMA-B160
xxx
3-PH; 380…420V AC; 50 Hz /
440…480V AC; 60 Hz
2.31
1.10
30
1400
MM-BLWR-160-2B-C
MMA-B180
xxx
3-PH; 380…420V AC; 50 Hz /
440…480V AC; 60 Hz
3.14
1.50
35
1600
MM-BLWR-180-2B-C
MMA-B225
xxx
3-PH; 380…420V AC; 50 Hz /
440…480V AC; 60 Hz
4.51
2.20
48
1800
MM-BLWR-225-2B-C
SHOCK HAZARD:
To avoid an electric shock hazard, verify that the voltage has discharged completely before servicing.
Table 51 - Radial Blower Filter Specifications
Filter Dimensions
Motor Cat. No.
Dimensions
mm (in.)
Filter Folds
MMA-B132
xxx
245 x 220 x 48 (9.6 x 8.7 x 1.9)
5
MMA-B160
xxx
300 x 260 x 48 (11.8 x 10.2 x 1.9)
6
MMA-B180
xxx
350 x 350 x 48 (13.8 x 13.8 x 1.9)
7
MMA-B225
xxx
440 x 440 x 48 (17.3 x 17.3 x 1.9)
8
NOTE:
When
cleaning filter, blow
compressed air
from the internal
surface outward.
Air filter path.
Remove
screws (x2)
(hand-tighten)