background image

5/25/2018

530800 - Fuse and Line Filter sizing for the Kinetix 5500 drive

https://rockwellautomation.custhelp.com/app/answers/detail/a_id/530800

5/10

characteristics such as inrush in order to have a symmetrical AC power up.
AC/DC sharing will support the use of the capacitor module WHEN three phase power is utilized.   In this
frame 2 drive, 2198-H015-ERS, even though single phase configuration is available, the 2198-CAPMOD-
1300 cannot be used.
For a line filter use, the total AC amps is approximately 20.8 Amps RMS for this configuration.   A 2198-
DB20-F is 20 Amps continuous and cannot be used.  Therefore, use 2198-DB42-F as that can handle the
current requirements of the AC/D Sharing configuration shown above.
AC Sharing MUST be used with both AC sharing bus bar and DC control power bus bars.
The 2198-H015-ERS is a frame 2 Kinetix 5500, as referenced in the 

Kinetix 5500 User Manual

(http://literature.rckwellautomation.com/idc/groups/literature/documents/um/2198-um001_-en-p.pdf) & 

Kinetix

Servo Drive Technical Documentation

 (http://gmc-td003_-en-p.pdf/)

Use Qty 1, 2198-H040-ADP-IN  for the first 2198-H015-ERS which will allow you to bring in both AC L1-
L3(and ground)  DC control power and have a connection for the first DC bus bar to drive 2.
Use Qty 3, 2198-H040-ADP-T for each of the next 4, 2198-H015-ERS to allow AC sharing.,DC control power
sharing and DC bus power sharing
In this configuration, qty 4, 2198-H015-ERS are used.  Each converter section can put 1.6 kW (230 Vac) or
3.2 kW(460 Vac) when in a Shared DC bus or standalone inverter use.  When used in Shared AC/DC
configuration, the SUM of the converter output must be derated or limited to 70% of continuous power
available.  In this instance, 4 x 1.6 kW x .7 = 4.48 kW (230 Vac) or 4 x 3.2 kW x .7 = 8.96 kW (460 Vac).  The
2198-HR015-ERS inverter power continuous out in this configuration cannot exceed either of these values.
Three phase power MUST be used for AC/DC Sharing.  Single Phase operation is not supported in AC/DC
Sharing.

4. 

SHARED DC BUS

Shared DC Bus is comparable operation to the Kinetix 6000 series where the DC bus is supplied by the leader
drive to the followers that are on the DC bus.

Содержание Allen-Bradley Kinetix 5500

Страница 1: ...Kinetix 5500 Design Guide http literature rockwellautomation com idc groups literature documents rm gmc rm009_ en p pdf Publication GMC RM009 The Kinetix Servo Drive Technical Documentation http gmc...

Страница 2: ...98 um001_ en p pdf Chapter 2 Planning the Kinetix 5500 Drive System Installation and the Kinetix Servo Drive Technical Documentation http gmc td003_ en p pdf Recommended Components for the Stand Alone...

Страница 3: ...ferent AC line characteristics such as inrush in order to have a symmetrical AC power up AC Sharing configuration does not support use of the 2198 capacitor module for similar reasons as item 2 above...

Страница 4: ...bus capacitive absorption and more ability to handle regenerative energy on the entire DC bus This configuration MUST be used with the available AC bus bars DC bus bars and DC control power bus bars S...

Страница 5: ...p pdf Kinetix Servo Drive Technical Documentation http gmc td003_ en p pdf Use Qty 1 2198 H040 ADP IN for the first 2198 H015 ERS which will allow you to bring in both AC L1 L3 and ground DC control...

Страница 6: ...40 ERS use KTK R 25 fuses Other recommended fusing can be found in the Kinetix Servo Drive Technical Documentation http gmc td003_ en p pdf With DC shared the leader converter power MUST be able to su...

Страница 7: ...oth DC Shared power and DC control power bus bars The 2198 H040 ERS is a frame 3 Kinetix 5500 as referenced in the Kinetix 5500 User Manual http literature rckwellautomation com idc groups literature...

Страница 8: ...For configuration use Qty 2 2198 H015 ERS Qty 1 2198 H008 ERS and Qty 1 2198 H003 ERS A 2198 CAPMOD 1300 is also specified for adding DC bus capacitance and ability to assist in DC bus capacitance abs...

Страница 9: ...ith DC bus and DC control power sharing Three phase power to the leader module MUST be used for Shared DC configuration Single Phase operation is not supported in Shared DC configuration The largest l...

Страница 10: ...RETO AT ANY TIME IN ITS SOLE DISCRETION WITHOUT NOTICE FURTHER ALL INFORMATION CONVEYED HEREBY IS PROVIDED TO USERS AS IS IN NO EVENT SHALL ROCKWELL BE LIABLE FOR ANY DAMAGES OF ANY KIND INCLUDING DIR...

Отзывы: