Rockwell Automation Publication 2071-UM001E-EN-P - November 2013
97
Configure Your Drive for Communication with a Personal Computer Running Connected Components Workbench Software
Chapter 7
Configure the Plug in Serial
Port on the Micro830 or
Micro850 Controller
1.
Under Plug-In Modules right-click the first empty slot and choose
Communication>2080-SERIALISOL.
2.
Under Common Settings, from the Driver pull-down menu, choose
Modbus RTU.
If necessary, change the other properties to match the dialog box below.
3.
Under Protocol Control settings, from the Media pull-down menu, choose
RS485.
4.
Right-click the controller icon and choose Build.
Program the Controller for
Modbus Communication with
a Kinetix 3 Drive
Please refer to Kinetix 3 Motion Control Indexing Device Building Block Quick
Start, publication
and Micro800 Programmable Controllers General
Instructions Reference Manual, publication
for information about
Modbus messaging and programming the Micro800 controllers and Kinetix 3
drive.
Содержание Allen-Bradley Kinetix 3 2071-A10
Страница 4: ...4 Rockwell Automation Publication 2071 UM001E EN P November 2013 Summary of Changes Notes ...
Страница 8: ...8 Rockwell Automation Publication 2071 UM001E EN P November 2013 Table of Contents Notes ...
Страница 16: ...16 Rockwell Automation Publication 2071 UM001E EN P November 2013 Chapter 1 Start Notes ...
Страница 78: ...78 Rockwell Automation Publication 2071 UM001E EN P November 2013 Chapter 4 Connect the Kinetix 3 Drive Notes ...
Страница 84: ...84 Rockwell Automation Publication 2071 UM001E EN P November 2013 Chapter 5 Using the Keypad Interface Notes ...
Страница 130: ...130 Rockwell Automation Publication 2071 UM001E EN P November 2013 Appendix A Interconnect Diagrams Notes ...