Rockwell Automation Publication 440G-UM001B-EN-P - May 2016
51
Wiring Examples
Chapter 5
Cat 1 Stop with Speed Monitored Guard Lock Function with
Kinetix 300 and GLP Safety Relay
A1
A2
L12
S54
L11
SL1
0
1
2
3
4
5
6
7
8
9
1
2
3
4
5
8
10
9
P22
P12
AP
LOGIC
6
7
0
1
2
3
4
5
6
7
8
9
S22
S12
Y32
S44
A1
X14
X24
51
L61
GLP
889M-F19RM-X
24V DC
872C-D8NP18-E5 (2)
0V DC
440R-GL2S2P
SL2
U
R
U
A
U
A
*OT
*OL
+24V DC
COM
1
2
3
4
5
6
Kinetix 300
L1
L3
M
I/O
L2
R
U
IN_x_COM
1
0
10
8
7
6
5
4
3
2
1
X3
IMM
0V
UA
IMP1
IMP2
8
7
6
5
4
3
2
1
X3
IMM
IMP
*
0V
UA
442G-MAB PTR
Note 1: U
: Connected to 24V internally in MAB
OL: True when the door is closed, the bolt is extended and locked.
OT: True when the door is closed and the bolt is extended, locked
or not.
A
In this example
The E-stop initiates a category 1 stop function.
The unlock request provides a category 1 stop function.
The MAB and GLP provide a speed monitored guard lock function.
The MAB and GLP provide a prevention of unexpected start-up function.
Hardware Rev. B
MAB cover
Reset/Lock
Blue
Brown
Yellow/
Brown
Green/
Black
Red/Blue
Unlock Cmd A
- see Note 1
Unlock Cmd B
Violet
Gray/Brown
White/Green
Pink
Blue
Bl
ac
k
Br
ow
n
Bl
ue
Bla
ck
Br
ow
n
- see Note 3
White
Gray/Pink
Reset MAB
MAB cover
Unlock Request
Digital Input
(IOD) Connector
- see Note 2
Rev. B
Rev. A
Note 2: When using a Harfware Rev. A MAB, connect the violet wire to terminal 51 of the
GLP. The gray/brown wire must remain unconnected.
Note that the terminal designations of terminals X3.6 and X3.7 are different on
Hardware Rev. A and Hardware Rev. B MAB.
Note 3: The digital input, configured for abort index in MotionView software, must be
active-high when the safety function is requested. Digital input common
(IN_x_COM) must be used in this signal activation/de-activation transition.
Safe Tongue-off (S10)
Connector with
DWiring Header
Status
Safety Input 1
Safety Common
Safety Input 2
Содержание Allen-Bradley Guardmaster 442G-MAB B-U Series
Страница 12: ...12 Rockwell Automation Publication 440G UM001B EN P May 2016 Chapter 1 General Description Notes ...
Страница 26: ...26 Rockwell Automation Publication 440G UM001B EN P May 2016 Chapter 3 Installation and Wiring Notes ...
Страница 58: ...58 Rockwell Automation Publication 440G UM001B EN P May 2016 Chapter 6 Specifications Notes ...
Страница 66: ...66 Rockwell Automation Publication 442G UM001B EN P May 2016 Appendix A Troubleshooting and Assistance Notes ...
Страница 67: ......