Publication 1756-UM001A-EN-P - September 2000
Communicate with 1771 I/O Over a ControlNet
™
Network
5-5
H.
Type the rate at which the fastest device in the chassis must
update.
•
Use a power of two times the ControlNet NUT.
•
For example, if the NUT is 5 ms, type a rate of 5, 10, 20 ms,
etc.
I.
Initially, do you want the module to communicate with the
controller?
J.
If communication with the module fails, how do you want the
controller to respond?
K.
Click
Finish
.
42401
I.
J.
H.
If:
Then:
Notes:
Yes
Leave the check box cleared
(unchecked).
No
Select the check box.
When you test this portion of the
system, clear the check box.
ATTENTION
!
If communication with a module fails, the
controller operates on old data from the
module. To avoid potential injury or damage,
either monitor communications with modules
or configure modules to produce a major fault
if communications fail.
If you want the
controller to:
Then:
Notes:
fault (major fault)
Select the check box.
continue operating
Leave the check box
cleared (unchecked).
Monitor the connection
using ladder logic.
Содержание Allen-Bradley ControlLogix 1756-L Series
Страница 1: ...ControlLogix System 1756 Lx User Manual ...
Страница 10: ...Publication 1756 UM001A EN P September 2000 Table of Contents vi ...
Страница 64: ...Publication 1756 UM001A EN P September 2000 4 16 Communicate with 1756 I O Notes ...
Страница 90: ...Publication 1756 UM001A EN P September 2000 6 16 Communicate with 1794 I O Over a ControlNet Network Notes ...
Страница 108: ...Publication 1756 UM001A EN P September 2000 7 18 Communicate with Another Controller over a ControlNet Network Notes ...
Страница 112: ...Publication 1756 UM001A EN P September 2000 8 4 Route PLC 5 Messages Between ControlNet Networks Notes ...
Страница 119: ...Publication 1756 UM001A EN P September 2000 Communicate with a PanelView Terminal Over a ControlNet Network 9 7 ...
Страница 152: ...Publication 1756 UM001A EN P September 2000 11 4 Monitor Connections Notes ...
Страница 160: ...Publication 1756 UM001A EN P September 2000 12 8 Communicate with a DeviceNet Device Notes ...
Страница 188: ...Publication 1756 UM001A EN P September 2000 14 8 Route PLC 5 or SLC 500 Messages From a DH Network Notes ...
Страница 204: ...Publication 1756 UM001A EN P September 2000 15 16 Communicate Over a Remote I O Network Notes ...
Страница 232: ...Publication 1756 UM001A EN P September 2000 18 18 Configure DF1 Master and Slave Communications Notes ...
Страница 266: ...Publication 1756 UM001A EN P September 2000 21 10 Maintain the Battery Notes ...
Страница 286: ...Publication 1756 UM001A EN P September 2000 B 18 Estimate Execution Time Notes ...
Страница 300: ...Publication 1756 UM001A EN P September 2000 C 14 Estimate Memory Use Notes ...
Страница 305: ......
Страница 307: ...ControlLogix System User Manual ...