background image

Installation Instructions

Original Instructions

Kinetix 5500 Servo Drives

Catalog Numbers 2198-H003-ERS, 2198-H008-ERS, 2198-H015-ERS, 2198-H025-ERS, 2198-H040-ERS, 2198-H070-ERS, 
2198-H003-ERS2, 2198-H008-ERS2, 2198-H015-ERS2, 2198-H025-ERS2, 2198-H040-ERS2, 2198-H070-ERS2

Summary of Changes

This publication contains new and updated information as indicated in the following table.

About the Kinetix 5500 Drives

Kinetix® 5500 servo drives provide an Integrated Motion over the EtherNet/IP network solution for applications with output power and current 
requirements in the range of 0.2…14.6 kW and 1.4…32.5 A 0-pk, respectively.

See the Kinetix 5500 Servo Drives User Manual, publication 

2198-UM001

, for detailed information on wiring, applying power, troubleshooting, 

and integration with ControlLogix® 5570, ControlLogix 5580, and GuardLogix® 5570, or CompactLogix™ 5370 and Compact GuardLogix 5370 
controllers.

Topic

Page

Summary of Changes

1

About the Kinetix 5500 Drives

1

Catalog Number Explanation

2

Before You Begin

2

Remove the Grounding Screws in Ungrounded Power Configurations

2

Install the Kinetix 5500 Servo Drive

3

Connector Data

6

Wiring Requirements

9

Attach the Motor Cable Shield Clamp

10

Circuit Breaker/Fuse Selection

12

Motor Overload Protection

14

Additional Resources

15

Topic 

Page

Added ‘impedance grounded’ when ever ungrounded and corner-grounded power configurations are mentioned 

2…3

Updated callouts in Grounding Screw figure and updated text in Grounding Screw table

3

Added 2198-H

xxx

-ERS2 safety connector view and shared-bus wiring connectors to Features and Indicators figure

6

Updated Wiring Requirements table with text and values

9

Added Circuit Breaker/Fuse Selection tables 

12…14

Updated text in Motor Overload Protection with new thermal retention feature in drive firmware 4.001 or later

14

Содержание Allen-Bradley 2198-H***-ERS Series

Страница 1: ...80 and GuardLogix 5570 or CompactLogix 5370 and Compact GuardLogix 5370 controllers Topic Page Summary of Changes 1 About the Kinetix 5500 Drives 1 Catalog Number Explanation 2 Before You Begin 2 Remo...

Страница 2: ...r impedance grounded power configurations Removing the screws involves gaining access opening the side door and removing the screws Removing the grounding screws in multi axis configurations is best d...

Страница 3: ...mpliance Reduced electrical noise Most stable operation Reduced voltage stress on components and motor bearings AC fed ungrounded Corner grounded Impedance grounded Both screws removed Helps avoid sev...

Страница 4: ...n Refer to the Kinetix Servo Drives Technical Data publication GMC TD003 for Kinetix 5500 drive dimensions In multi axis shared bus configurations drives must be spaced by aligning the zero stack tab...

Страница 5: ...at No Frame A mm in B mm in C mm in D mm in E mm in Drill Hole Patterns F mm in G mm in 2198 H003 ERSx 1 50 1 97 170 6 69 200 7 87 226 8 90 215 8 46 193 68 7 62 4 51 0 18 2198 H008 ERSx 2198 H015 ERSx...

Страница 6: ...13 Link Activity status indicators 20 24V control input power CP connector 7 Zero stack mounting tab cutout 14 Motor power MP connector 21 Safe torque off STO connector 3 applies to only 2198 Hxxx ERS...

Страница 7: ...2 DC DC Pin Description Signal 1 DC bus connections DC 2 DC CP Pin Description Signal 1 24V power supply customer supplied 24V 2 24V common 24V MP Pin Description Signal Color U Three phase motorpowe...

Страница 8: ...put 1 This is a dual function input IN1 1 1 This signal has dual functionality You can use IN1 IOD 1 as registration or Home input 2 I O common for customer supplied 24V supply COM 3 24V current sinki...

Страница 9: ...icalData publication KNX TD004 for cable specifications 8 0 0 31 0 5 0 6 4 4 5 3 2198 H070 ERSx 2 5 6 4 14 10 10 0 0 39 0 5 0 8 4 4 7 1 2198 Hxxx ERSx PELV SELV 24V power single axis CP connector CP 1...

Страница 10: ...is Motor Cable Shield Clamp 2198 KITCON DSL Motor Feedback Connector Kit Motor Power MP Connector Motor Brake BC Connector Exposed shield braid under clamp Feedback cable routed around the shield clam...

Страница 11: ...attaching the motor power brake shield clamp IMPORTANT If the power brake cableshield has a loose fit inside the shield clamp insert theclamp spacer between the shield clamp and the drive to reduce t...

Страница 12: ...ications Drive Cat No Drive Voltage nom Phase Bussmann Fuses Cat No Molded Case CB Cat No DIN gG Fuses Amps max Molded Case CB Cat No 2198 H003 ERSx 240V Single phase KTK R 2 140U D6D2 B10 2 140U D6D2...

Страница 13: ...SP 140G G6C3 C40 35 140G G6C3 C40 Kinetix 5500 Drive Cat No Drive Voltage three phase nom Bussmann Fuses Cat No Molded Case CB Cat No 2 Axes 3 Axes 4 Axes 5 Axes 2 Axes 3 Axes 4 Axes 5 Axes 2198 H003...

Страница 14: ...meets the following UL requirements for solid state overload protection Refer to your servo drive user manual for the interconnect diagram that illustrates the wiring between your motor and drive Kin...

Страница 15: ...hnical Data publication KNX TD004 Provides product specifications for Bulletin 2090 motor and interface cables low profile connector kits drive power components and other servo drive accessory items K...

Страница 16: ...your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at http literature rockwellautomation com idc groups literature documents...

Отзывы: