92
Rockwell Automation Publication 2198-UM001D-EN-P - May 2014
Chapter 5
Connecting the Kinetix 5500 Drive System
Figure 53 - 2198-H2DCK Converter Kit Pinout
Motor Feedback Cable Preparation
Follow these steps to prepare feedback cables.
1.
Remove 115 mm (4.5 in.) of cable jacket and 103 mm (4.0 in.) of cable
shield.
2.
Determine the length for each of the 10 wires and trim as necessary.
3.
Remove 5.0 mm (0.2 in.) of insulation from the end of each wire.
14
11
10
7
6
5
4
3
2
1
Terminal
Signal
Wire Color
Strip Length
mm (in.)
Torque Value
N•m (lb•in)
1 SIN+ Black
5.0 (0.2)
0.22…0.25
(1.9…2.2)
2 SIN–
White/Black
3 COS+
Red
4 COS–
White/Red
5
DATA+
Green
6 ECOM
(1)
(1) The ECOM and TS- connections are tied together and connect to the cable shield.
White/Gray
7
EPWR_9V
(2)
(2) The converter kit generates 5V and 9V from a 12V supply coming from the drive. The 5V supply is
used by 5V encoders in 230V motors. The 9V supply is used by 9V encoders in 460V motors.
Orange
10
DATA– White/Green
11
TS+
White/Orange
14
EPWR_5V
(2)
Gray
10-pin
Connector
IMPORTANT
This length of wire is needed to provide a service loop for the longest
wires terminated at the 10-pin connector. However, most wires need to
be trimmed shorter, depending on the terminal they are assigned to.
12.0 (0.5)
5.0 (0.2)
115 (4.5)
103 (4.0)
Cable Jacket
Cable Shield
Dimensions are in mm (in.)
Содержание Allen-Bradley 2198-CAPMOD-1300
Страница 28: ...28 Rockwell Automation Publication 2198 UM001D EN P May 2014 Chapter 1 Start Notes ...
Страница 202: ...202 Rockwell Automation Publication 2198 UM001D EN P May 2014 Appendix A Interconnect Diagrams Notes ...
Страница 212: ...212 Rockwell Automation Publication 2198 UM001D EN P May 2014 Appendix B Upgrade the Drive Firmware Notes ...
Страница 228: ...228 Rockwell Automation Publication 2198 UM001D EN P May 2014 Appendix D Induction Motor Support Notes ...
Страница 234: ...234 Rockwell Automation Publication 2198 UM001D EN P May 2014 Appendix E EC Certifications Notes ...
Страница 243: ......