152
Rockwell Automation Publication 2198-UM001D-EN-P - May 2014
Chapter 7
Troubleshooting the Kinetix 5500 Drive System
Table 72 - Drive Behavior, NODE FLT Fault Codes
Exception Fault Code
Exception Text
Permanent
Magnet Motor
Induction Motor
Fault Action
Best Available
Stopping Action
(applies to major faults)
Ignor
e
Alarm
Mi
n
or F
aul
t
Major F
ault
NODE FLT 01 – LATE CTRL UPDATE
Control Connection Update Fault
X
X
X
Decel/Disable
NODE FLT 02 – PROC WATCHDOG
Processor Watchdog Fault
X
X
X
Disable/Coast
NODE FLT 03 – HARDWARE
Hardware Fault
X
X
X
Disable/Coast
NODE FLT 05 – CLOCK SKEW FLT
Clock Skew Fault
X
X
X
Disable/Coast
NODE FLT 06 – LOST CTRL CONN
Lost Controller Connection Fault
X
X
X
Decel/Disable
NODE FLT 07 – CLOCK SYNC
Clock Sync Fault
X
X
X
Disable/Coast
NODE FLT 09 – DUPLICATE IP ADDRESS
Duplicate IP Address Fault
X
X
X
Disable/Coast
Содержание Allen-Bradley 2198-CAPMOD-1300
Страница 28: ...28 Rockwell Automation Publication 2198 UM001D EN P May 2014 Chapter 1 Start Notes ...
Страница 202: ...202 Rockwell Automation Publication 2198 UM001D EN P May 2014 Appendix A Interconnect Diagrams Notes ...
Страница 212: ...212 Rockwell Automation Publication 2198 UM001D EN P May 2014 Appendix B Upgrade the Drive Firmware Notes ...
Страница 228: ...228 Rockwell Automation Publication 2198 UM001D EN P May 2014 Appendix D Induction Motor Support Notes ...
Страница 234: ...234 Rockwell Automation Publication 2198 UM001D EN P May 2014 Appendix E EC Certifications Notes ...
Страница 243: ......