222
Rockwell Automation Publication 2198-UM001D-EN-P - May 2014
Appendix C
Sizing Multi-axis Shared-bus Configurations
Energy Calculations
The Kinetix 5500 servo drives have internal shunt resistors for dissipating
excessive energy. In addition, Bulletin 2097 external shunt resistors and Bulletin
2198 capacitor modules are available to increase the shared DC bus capacitance.
Use this table to calculate the total energy absorbing potential (joules) and
determine if a capacitor module or external shunt resistor is needed.
Table 91 - Energy Absorbing Potential
Refer to Motion Analyzer software, version 7.0 or later, for custom shunt sizing.
Kinetix 5500 Drive
Cat. No.
Internal Shunt
J
External Shunt
kJ
Capacitor Module
(1)
J
Capacitor Module, max
(2)
J
2198-H003-ERS
x
427.09
12.51
N/A
N/A
2198-H008-ERS
x
554.4
554.4
2198-H015-ERS
x
549.01
12.521
676.32
676.32
2198-H025-ERS
x
575.223
12.549
702.53
957.162
2198-H040-ERS
x
601.434
22.647
728.74
983.373
2198-H070-ERS
x
1827.01
27.218
1954.3
2208.95
(1) Value assumes the use of one servo drive and one capacitor module.
(2) Value assumes the use of one servo drive and the maximum number of capacitor modules allowed.
Содержание Allen-Bradley 2198-CAPMOD-1300
Страница 28: ...28 Rockwell Automation Publication 2198 UM001D EN P May 2014 Chapter 1 Start Notes ...
Страница 202: ...202 Rockwell Automation Publication 2198 UM001D EN P May 2014 Appendix A Interconnect Diagrams Notes ...
Страница 212: ...212 Rockwell Automation Publication 2198 UM001D EN P May 2014 Appendix B Upgrade the Drive Firmware Notes ...
Страница 228: ...228 Rockwell Automation Publication 2198 UM001D EN P May 2014 Appendix D Induction Motor Support Notes ...
Страница 234: ...234 Rockwell Automation Publication 2198 UM001D EN P May 2014 Appendix E EC Certifications Notes ...
Страница 243: ......