Rockwell Automation Publication 2094-UM001D-EN-P - May 2010
245
Appendix
D
DC Common Bus Applications
Introduction
This appendix provides integration procedures specific to Kinetix 6000
multi-axis drive systems configured for DC common bus. The procedure involves
calculating capacitance values and setting the Additional Bus Capacitance
parameter by using DriveExplorer or RSLogix 5000 software.
Before You Begin
These procedures assume you have mounted and wired your Kinetix 6000 DC
common-bus system.
Before you set the Additional Bus Capacitance (Add Bus Cap) parameter in
DriveExplorer or RSLogix 5000 software, you need to calculate these values:
•
Total bus capacitance
•
Additional bus capacitance
Topic
Page
Calculate Total Bus Capacitance
Calculate Additional Bus Capacitance
Bulletin 2094 Drive Capacitance Values
Common Bus Capacitance Example
Set the Additional Bus Capacitance Parameter with DriveExplorer Software
Содержание Allen-Bradley 2094-BC01-M01-S
Страница 4: ...4 Rockwell Automation Publication 2094 UM001D EN P May 2010 Summary of Changes Notes...
Страница 10: ...10 Rockwell Automation Publication 2094 UM001D EN P May 2010 Table of Contents Notes...
Страница 126: ...126 Rockwell Automation Publication 2094 UM001D EN P May 2010 Chapter 5 Connecting the Kinetix 6000 Drive System Notes...
Страница 228: ...228 Rockwell Automation Publication 2094 UM001D EN P May 2010 Appendix B Interconnect Diagrams Notes...
Страница 270: ...270 Rockwell Automation Publication 2094 UM001D EN P May 2010 Appendix F RBM Module Interconnect Diagrams Notes...
Страница 278: ...278 Rockwell Automation Publication 2094 UM001D EN P May 2010 Index Notes...
Страница 279: ......