Rockwell Automation Publication 193-UM014A-EN-P - July 2011
43
Chapter
6
5.
Click Save, then cycle power on the EtherNet/IP Communications
Auxilliary.
An ADR download is performed immediately before an I/O connectionis
allocated by the DeviceNet master.
If the download is unsuccessful, an “ADR Error” for the appropriate node
will be reported inthe corresponding “Scan List Entry Status Word”. If the
electronic keys for the device at a given node address do not match the
saved electronic keys for that node address, no ADR download will take
place, an I/O connection will not be allocated, and a “Keying Mismatch”
will be reported in the corresponding “Scan List Entry Status Word”.
A warning list will appear after enabling the ADR and a change has been
made to the scan list.
AAR (Auto Address Recovery) is also supported by the EtherNet/IP
Communications Auxilliary. When the EtherNet/IP Communications
Auxilliary detects a node is missing from the scan list and a module matching the
Содержание Allen-Bradley 193-DNENCAT
Страница 1: ...User Manual Bulletin 193 EtherNet IP Communications Auxiliary Catalog Number 193 DNENCAT 193 DNENCATR...
Страница 10: ...10 Rockwell Automation Publication 193 UM014A EN P July 2011 Chapter 1...
Страница 28: ...28 Rockwell Automation Publication 193 UM014A EN P July 2011 Chapter 3...
Страница 68: ...68 Rockwell Automation Publication 193 UM014A EN P July 2011 Chapter 8 E mail Text...
Страница 74: ...74 Rockwell Automation Publication 193 UM014A EN P July 2011 Chapter 9 Device Parameters...
Страница 80: ...80 Rockwell Automation Publication 193 UM014A EN P July 2011 Chapter 10 Troubleshooting...
Страница 96: ...96 Rockwell Automation Publication 193 UM014A EN P July 2011 Appendix B...
Страница 97: ......