Rockwell Automation Publication 450L-UM001F-EN-P - March 2022
59
Chapter 5 System Configuration
Confirmation of a New
System Configuration
Perform a confirmation procedure of a new configuration when you reinsert
the plug-in to the light curtain stick with a changed DIP switch setting. The
request for such a confirmation is displayed via a 1 Hz red/green blinking STS
status indicator (
This process must be performed only once, after the first power-up of a plug-in
with new settings. It is not required at any following power-up (only when DIP
switches are changed again).
Figure 33 - Position of Optical Push Button and Status Indicator
Confirmation
shows the configuration timing sequence. The optical push button
must be activated two times for 5 seconds. Between the two activations, a
break of a maximum of 2 seconds is allowed.
Figure 34 - Configuration Process
Confirmation Procedure
To confirm a new configuration, follow these steps:
1. The status indicator STS blinks green/red (1 Hz, one time red, and one
time green per second, 50:50 duty cycle) which indicates that the stick is
in the configuration mode.
2. Actuate the optical push button for 5 seconds.
3. STS blinks green/red to indicate actuation with a frequency of 10 Hz and
50:50 duty cycle.
IMPORTANT
The confirmation procedure is not required when the receiver stick is
operated for the first time (brand new receiver). The STS status
indicator flashes red/green when a confirmation is required.
Confirmation of a system configuration must only be performed when
the receiver stick was previously operated with another configuration
or when the receiver stick was previously operated with another
transmitter.
If the receiver plug-in is exchanged with a new plug-in with the same
plug-in type and DIP switch settings as the original one, no confirmation
procedure is required.
Also, no configuration confirmation procedure is required for a
complete pair of 450L safety light curtain transceiver sticks out-of-the-
box.
Optical Push Button
Status Indicator
5 s
5 s
2 s
1
5
2
4
6
3
Optical Push Button Released
Optical Push Button Activated
Содержание Allen-Bradley 140M
Страница 8: ...8 Rockwell Automation Publication 450L UM001F EN P March 2022 Table of Contents Notes ...
Страница 20: ...20 Rockwell Automation Publication 450L UM001F EN P March 2022 Chapter 2 Safety Concepts Notes ...
Страница 108: ...108 Rockwell Automation Publication 450L UM001F EN P March 2022 Chapter 7 Status Indicators and Troubleshooting Notes ...
Страница 114: ...114 Rockwell Automation Publication 450L UM001F EN P March 2022 Chapter 8 Safety Instructions Notes ...
Страница 184: ...184 Rockwell Automation Publication 450L UM001F EN P March 2022 Appendix B Typical Installations Notes ...
Страница 190: ...190 Rockwell Automation Publication 450L UM001F EN P March 2022 Index ...
Страница 191: ...Rockwell Automation Publication 450L UM001F EN P March 2022 191 GuardShield Safety Light Curtain User Manual ...