56
Rockwell Automation Publication 450L-UM001F-EN-P - March 2022
Chapter 5 System Configuration
450L-APR-BL-5 Connection
Plug-in
shows the function and default settings for the M12 5-pin blanking
receiver (450L-APR-BL-5) plug-in that is inserted in a 450L transceiver stick.
Not applicable to 450L PAC safety light curtains.
450L-APR-MU-8 Connection
Plug-in
shows the function and default settings for the M12 8-pin muting
receiver plug-in (450L-APR-MU-8) inserted in a 450L safety light curtain
transceiver stick.
Table 25 - Function and Default Settings
Switch Number
Switch Function
Default
Description
1
450L-E only: Software
Configuration
OFF
OFF: Disabled
ON: Enabled
2
Low Range Activation
OFF
OFF: Disabled
ON: Enabled
3
450L-E and 450L PAC only:
Activates Beam Coding
OFF
OFF: Disabled
ON: Enabled
4
450L-E only: Activates
Interference Rejection
OFF
OFF: Disabled
ON: Enabled
5
450L-E only:
Teach-in Blanking
OFF
OFF: Disabled
ON: Enabled
6
450L-E only:
Combination activates the
following start modes:
• No reduced resolution
• Reduced resolution 1
lens
• Reduced resolution 2
lenses
OFF
• DIP 6: OFF, DIP 7: OFF:
Reduced resolution
disabled (Default)
• DIP 6: OFF, DIP 7: ON:
Reduced resolution 2
beam
• DIP 6: ON, DIP 7:OFF:
Reduced resolution 1
beam
• DIP 6: ON, DIP 7:ON:
Invalid selection (error)
7
OFF
8
—
OFF
—
Table 26 - Function and Default Settings
Switch Number
Switch Function
Default
Description
1
450L-E only: Software
Configuration
OFF
OFF: Disabled
ON: Enabled
2
Low Range Activation
OFF
OFF: Disabled
ON: Enabled
3
450L-E and 450L PAC only:
Activates Beam Coding
OFF
OFF: Disabled
ON: Enabled
4
450L-E only: Activates
Interference Rejection
OFF
OFF: Disabled
ON: Enabled
5
Combination activates one
of the following start
modes:
• Automatic start
• Manual (re)start
• Manual cold start
• Manual start with off
function
OFF
• DIP 5: OFF, DIP 6: OFF:
Automatic start (Default)
• DIP 5: ON, DIP 6: OFF:
Manual (re)start
• DIP 5: OFF, DIP 6: ON:
Manual cold start
• DIP 5: ON, DIP 6: ON:
Manual start with off
function
6
OFF
7
External Device Monitoring OFF
OFF: Disabled
ON: Enabled
8
450L-E only:
Muting or Blanking
OFF
OFF: see blanking modes in
ON: see muting modes in
9
450L-E only:
Teach-in Blanking
OFF
OFF: Disabled
ON: Enabled
Содержание Allen-Bradley 140M
Страница 8: ...8 Rockwell Automation Publication 450L UM001F EN P March 2022 Table of Contents Notes ...
Страница 20: ...20 Rockwell Automation Publication 450L UM001F EN P March 2022 Chapter 2 Safety Concepts Notes ...
Страница 108: ...108 Rockwell Automation Publication 450L UM001F EN P March 2022 Chapter 7 Status Indicators and Troubleshooting Notes ...
Страница 114: ...114 Rockwell Automation Publication 450L UM001F EN P March 2022 Chapter 8 Safety Instructions Notes ...
Страница 184: ...184 Rockwell Automation Publication 450L UM001F EN P March 2022 Appendix B Typical Installations Notes ...
Страница 190: ...190 Rockwell Automation Publication 450L UM001F EN P March 2022 Index ...
Страница 191: ...Rockwell Automation Publication 450L UM001F EN P March 2022 191 GuardShield Safety Light Curtain User Manual ...