Rockwell Automation Publication 1756-IN048D-EN-P - March 2021

3

GuardLogix 5580 Controllers Installation Instructions

Product Advisories

ATTENTION: 

• In case of malfunction or damage, no attempts at repair should be made. The module should be returned to the manufacturer for repair. 

Do not dismantle the module.

• The USB port is intended for temporary local programming purposes only and not intended for permanent connection. The USB cable 

is not to exceed 3.0 m (9.84 ft) and must not contain hubs.

• Use only a soft dry anti-static cloth to wipe down equipment. Do not use any cleaning agents.

• When installed in a 1756 Series C Chassis, this equipment is certified for use only within the surrounding air temperature range 

of 0…60 °C (32…140 °F). The equipment must not be used outside of this range. 

• When installed in a 1756 Series B Chassis, this equipment is certified for use only within the surrounding air temperature range 

of 0…50 °C (32…122 °F). The equipment must not be used outside of this range.

WARNING: 

• When you press the reset button while power is on, an electrical arc can occur. This could cause an explosion in hazardous location installations. Be 

sure that power is removed or the area is nonhazardous before proceeding.

• Do not use the USB port in hazardous locations.

North American Hazardous Location Approval

The following information applies when operating this equipment in 

hazardous locations.

Informations sur l’utilisation de cet équipement en environnements dangereux.

Products marked "CL I, DIV 2, GP A, B, C, D" are suitable for use in Class I Division 

2 Groups A, B, C, D, Hazardous Locations and nonhazardous locations only. Each 

product is supplied with markings on the rating nameplate indicating the 

hazardous location temperature code. When combining products within a 

system, the most adverse temperature code (lowest "T" number) may be used to 

help determine the overall temperature code of the system. Combinations of 

equipment in your system are subject to investigation by the local Authority 

Having Jurisdiction at the time of installation.

Les produits marqués "CL I, DIV 2, GP A, B, C, D" ne conviennent qu'à une utilisation en 

environnements de Classe I Division 2 Groupes A, B, C, D dangereux et non dangereux. 

Chaque produit est livré avec des marquages sur sa plaque d'identification qui 

indiquent le code de température pour les environnements dangereux. Lorsque 

plusieurs produits sont combinés dans un système, le code de température le plus 

défavorable (code de température le plus faible) peut être utilisé pour déterminer le 

code de température global du système. Les combinaisons d'équipements dans le 

système sont sujettes à inspection par les autorités locales qualifiées au moment de 

l'installation.

WARNING:

Explosion Hazard –

• Do not disconnect equipment unless power has been 

removed or the area is known to be nonhazardous. 

• Do not disconnect connections to this equipment unless 

power has been removed or the area is known to be 

nonhazardous. Secure any external connections that mate 

to this equipment by using screws, sliding latches, 

threaded connectors, or other means provided with

this product.

• Substitution of components may impair suitability for Class 

I, Division 2.

• If this product contains batteries, they must only be 

changed in an area known to be nonhazardous.

AVERTISSEMENT:

Risque d’Explosion – 

• Couper le courant ou s'assurer que l'environnement est classé non 

dangereux avant de débrancher l'équipement.

• Couper le courant ou s'assurer que l'environnement est classé non 

dangereux avant de débrancher les connecteurs. Fixer tous les 

connecteurs externes reliés à cet équipement à l'aide de vis, 

loquets coulissants, connecteurs filetés ou autres moyens fournis 

avec ce produit.

• La substitution de composants peut rendre cet équipement 

inadapté à une utilisation en environnement de Classe I, Division 2.

• S'assurer que l'environnement est classé non dangereux avant de 

changer les piles.

European Hazardous Location Approval

The following applies to products marked 

II 3 G: 

• Are Equipment Group II, Equipment Category 3, and comply with the Essential Health and Safety Requirements relating to the design 

and construction of such equipment given in Annex II to Directive 2014/34/EU. See the EC Declaration of Conformity at 

rok.auto/certifications

 for details.

• The type of protection is Ex nA IIC T4 Gc according to EN 60079-15.

• Comply to standards: EN 60079-0:2012+A11:2013, EN60079-15:2010, reference certificate number DEMKO13ATEX1325026X.

• Are intended for use in areas in which explosive atmospheres caused by gases, vapors, mists, or air are unlikely to occur, or are likely to occur only infrequently and 

for short periods. Such locations correspond to Zone 2 classification according to ATEX directive 2014/34/EU.

• May have catalog numbers followed by a "K" to indicate a conformal coating option.

Содержание 1756-L81ES

Страница 1: ...de up of a primary controller and a safety partner for SIL 3 applications that function together in a 1oo2 architecture With a safety partner installed GuardLogix controllers are Type approved and certified for use in safety applications up to and including SIL 3 per IEC 61508 EC Type approved for use in safety applications up to and including SIL CL3 per IEC 62061 EC Type approved for use in safe...

Страница 2: ...nnes formées selon le code de pratique en vigueur Si cet équipement est utilisé d une façon qui n a pas été définie par le fabricant la protection fournie par l équipement peut être compromise ATTENZIONE Prima di installare configurare ed utilizzare il prodotto o effettuare interventi di manutenzione su di esso leggere il presente documento ed i documenti elencati nella sezione Altre risorse rigua...

Страница 3: ...le code de température pour les environnements dangereux Lorsque plusieurs produits sont combinés dans un système le code de température le plus défavorable code de température le plus faible peut être utilisé pour déterminer le code de température global du système Les combinaisons d équipements dans le système sont sujettes à inspection par les autorités locales qualifiées au moment de l install...

Страница 4: ...permanent connection Do not use the USB port in hazardous locations Environment and Enclosure ATTENTION This equipment is intended for use in a Pollution Degree 2 industrial environment in overvoltage Category II applications as defined in EN 60664 1 at altitudes up to 2000 m 6562 ft without derating This equipment is not intended for use in residential environments and may not provide adequate pr...

Страница 5: ...C and series B 1756 A4 1756 A4K 1756 A7 1756 A7K 1756 A10 1756 A10K 1756 A13 1756 A13K 1756 A17 1756 A17 K Power supply standard 1756 PA72 1756 PA72K 1756 PA75 1756 PA75K 1756 PB72 1756 PB72K 1756 PB75 1756 PB75K 1756 PH75 1756 PC75 Power supply redundant 1756 PA75R 1756 PA75RK 1756 PB75R 1756 PB75RK 1756 PSCA2 1756 PSCA2K 139 6 mm 5 50 in 34 55 mm 1 360 in 145 2 mm 5 717 in Front view GuardLogix ...

Страница 6: ...ion you can use a Series B chassis derating to 50 C 122 F or Series C chassis with no restrictions WARNING When you insert or remove the module while backplane power is on an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is removed or the area is nonhazardous before proceeding Repeated electrical arcing causes excessive wear to contac...

Страница 7: ...therNet IP network then connect an RJ45 cable to the Ethernet port on the controller Confirm Installation After you insert the controller into the chassis and apply power the 4 character display and status indicators provide information about the controller See the ControlLogix 5580 and GuardLogix 5580 Controllers User Manual publication 1756 UM543 for information on how to interpret the 4 charact...

Страница 8: ... Ta 60 C 32 F Ta 140 F for Series C Chassis Note If operating above 55 C 131 F modules greater than 6 2W shall not be installed in slots adjacent to the controller Temperature operating SIL 3 PLe IEC 60068 2 1 Test Ad Operating Cold IEC 60068 2 2 Test Bd Operating Dry Heat IEC 60068 2 14 Test Nb Operating Thermal Shock 0 C Ta 60 C 32 F Ta 140 F for Series C Chassis 0 C Ta 50 C 32 F Ta 122 F for Se...

Страница 9: ...ollers User Manual publication 1756 UM543 Provides information on how to configure select I O modules manage communication develop applications and troubleshoot the ControlLogix 5580 controllers GuardLogix 5580 and Compact GuardLogix 5380 Controller Systems Safety Reference Manual publication 1756 RM012 Provides information on safety application requirements for GuardLogix 5580 and Compact GuardLo...

Страница 10: ...10 Rockwell Automation Publication 1756 IN048D EN P March 2021 GuardLogix 5580 Controllers Installation Instructions Notes ...

Страница 11: ...Rockwell Automation Publication 1756 IN048D EN P March 2021 11 GuardLogix 5580 Controllers Installation Instructions Notes ...

Страница 12: ...lectrical and Electronic Equipment WEEE Rockwell Automation maintains current product environmental compliance information on its website at rok auto pec At the end of life this equipment should be collected separately from any unsorted municipal waste Rockwell Automation Support Use these resources to access support information Documentation Feedback Your comments help us serve your documentation...

Отзывы: