The surge wa age ability of the
generator covers this extra power
requirement.
Item
Rated
(Running)
Wa age
Surge
Wa age
R2000i
1800
2000
Fig.46 -
Generator Wa age
The total running wa age requirement
of the electrical devices connected to
the generator should not exceed the
rated wa age of the generator itself.
To calculate the total wa age
requirement of the electrical devices
you plan to con
nect, fi
nd the rated (or
running) wa
age of each device. This
number should be listed somewhere on
the device or in its instruc on manual.
If this wa age cannot be found,
calculate it by mul plying the Voltage
requirement by the Amperage drawn:
Wa s = Volts x Amperes
When the rated wa age requirement
of each electrical device has been
determined, add these numbers to
fi
nd
the total rated wa age needed. If this
number exceeds the rated wa age of
the generator, DO
N
OT connect all
these devices. Select a combina on of
electrical devices, which have a total
rated wa age lower than or equal to
the rated wa age of the generator.
CAUTION:
The generator can run at
its surge wa age capacity for only a
short me. Connect electrical devices
requiring a rated
(running) wa
age
equal to or less than the rated wa age
of the generator. Never connect
devices requiring a rated wa age equal
to the surge wa ageof the generator.
This can trip the circuit protectors
(circuit breakers
).
NOTE
: Check the wa age on the
electrical device .
Once the electrical
devices that will be powered by the
generator have been determined,
connect these devices according to the
following procedure:
1. Plug in each electrical device, making
sure that the device is turned o
ff
.
2. Check the overload light and power
indicator light. If the overload light is on,
unplug the electronics, then restart the
generator before plugging the load
back in. If the reset bu on does not
reset, wait several minutes and try
again. If the power light s ll does not
come on, call the customer service
number for further instruc ons.
CAUTION:
Do not conne
ct 50Hz
loads to the generator.
SOME NOTES ABOUT POWER CORDS
Long or thin cords can drain the power
provided to an electrical device by the
generator. When using such cords,
allow for a slightly higher rated wa age
requirement by the electrical device.
See Fig.47 for recommended cords
based on the power requirement of the
electrical device.
Device
Requir
ement
s
Amps
2.5 5
7.5 10
15
Wa s
(120V)
300 600 900 1200 1800
Max.
Cord
Length
(
) by
#8
wire
NR NR NR NR
NR
#10
wire
NR NR 350 250
150