10
1.1 Technical specifications
Parameter
Modelo
ARc 73 TC
ARc 73 TC +Plus 180
ARc 93 TC
ARc 93 TC +Plus 180
Minimum - Maximum draught
11-13 Pa
Fuel consumption
3,4 kg/h
2,8 kg/h
3,5 kg/h
3,56 kg/h
Smoke mass flow rate
11,57 g/s
10,37 g/s
11,71 g/s
11,3 g/s
Performance
80,8 %
85,01 %
79 %
79.6%
Nominal output
11,4 kw
11 kW
12,1 kW
14,4 kW
Power range
7,5 – 13 kW
7,5– 13 kW
8,5 – 14,5 kW
8.5 – 14.5 kW
Average CO concentration at 13% of O
2
0,11 %
0,09%
0,07%
0,085%
Average NO
x
concentration at 13% of O
2
104,89 mg/Nm
3
71,50 mg/Nm
3
82,72 mg/Nm
3
126 mg/Nm
3
Average OGC concentration at 13% of O
2
98,78 mg/Nm
3
36,69 mg/Nm
3
52,66 mg/Nm
3
48 mg/Nm
3
Particle concentration at 13% of O
2
39,81 mg/Nm
3
38,69 mg/Nm
3
39,50 mg/Nm
3
20,20 mg/Nm
3
Medium draft (trial)
11 Pa
11,3 Pa
10 Pa
11,2 Pa
Net weight
114 kg
132 kg
161 kg
171,9 kg
Maximum authorized load (fuel)
3.5 kg
3.5 kg
5 kg
5 kg
Reload height
200 mm
200 mm
200 mm
200 mm
Logs length
450 mm
450 mm
600 mm
600 mm
Minimum flue height
4000 mm
Ø
Flue duct
180 mm
Ø
Air inlet
100 mm
Ø
Air outlet
120 mm
Inner fireplace room safety distances (back)
50 mm
50 mm
50 mm
50 mm
Inner fireplace safety distances (sides)
1000 mm
1000 mm
1000 mm
1000 mm
Outer fireplace safety distances (frontal)
1000 mm
1000 mm
1000 mm
1000 mm
Outer fireplace safety distances (sides)
1000 mm
1000 mm
1000 mm
1000 mm
Outer fireplace safety distances (back)
600 mm
600 mm
200 mm
200 mm
Fireplace room ventilation (entry - exit)
450 cm
2
Electrical wiring connection
Silicone hose 3*wire of 1.5 mm
2
Fan airflow (unit)
135 m
3
/h
Fan output (unit)
20 W
Minimum safety distance to the air outlets
2
2
4
4
Average temperature of smoke
250 mm
Type of combustion
217 ºC
178º C
250ºC
261,4ºC
Flue liner
INTERMITENT
Fuel
NOT SHARED
Humidity fuel logs
NATURAL WOOD
Certification year
12-20 % - two years under cover
Certificate number
2019
2017
2019
2021
Electrical wiring connection
19/20678-18601/2
17/14327-852/853 M3
19/20678-1856-1/2
1880-CPR-024-21
1.2 Breakdown of delivery components
(Make sure you have all the components described below in relation to the picture on section II of the ANNEXED document)
1.
Fireplace’s body.
2.
Heat-resistant spray paint for touch-ups.
3.
Fire grate.
4.
Heat-resistant glove.
5.
Cleaning cloth
6.
Exterior air inlet kit. (Exterior air inlet connector, connector support, tubular joint, metallic anchor, screws and nuts)
7.
Tool for handling registers and opening door.
8.
Documentation bag: output declaration, energy label, guarantee, technical sheet, and installation and operating
characteristics manual.
9.
Bag with screws.
10.
Outlet hot air connector (2x ARc 73 TC | ARc 73 TC +Plus 180, 4x ARc 93 TC | ARc 93 TC +Plus 180)
11.
Optional: + Plus 180 (ARc 73 TC +Plus 180 | ARc 93 TC +Plus 180)
1.3 Diagram of the equipment's measurements
See the ANNEXED document, section I, page 1.
ALL LOCAL STANDARDS, INCLUDING NATIONAL AND EUROPEAN REGULATIONS MUST BE COMPLIED WITH UPON
INSTALLATION OF THE EQUIPMENT.
THE INSTALLATION MUST BE PERFORMED BY A PROFESSIONAL. FAILURE TO COMPLY WITH THIS CLAUSE SHALL
EXONERATE THE MANUFACTURER FROM ANY RESPONSIBILITY.
2.1 Ground.
Make sure the ground where the appliance will be placed is able to support the weight of the device. If not, you will need
a load spreading plate for the equitable distribution of the equipment's weight. In case of doubt, please consult a specialist.
2.2 Flue liner.
It is mandatory to have a smoke-tight Flue liner going from the connecting point of the base to the outside in observation
of the smoke pipe diameter.
The good condition and suitability of this smoke pipe must be certified by a professional and
must also observe the relevant national regulations
. This flue liner must be T400 and G type should not be shared with other
devices (see Table 1.1 Technical specifications). In cases of too much draught, when the duct exceeds 7 meters in length, or the
measurement exceeds 20 Pa, the draft must be adjusted. To do this, use the second part of the baffle plate, to install it follow the
1. SPECIFICATIONS
2. REQUIREMENTS PRIOR TO INSTALLATION
Содержание ARc 73 TC +Plus 180
Страница 35: ...2 II 1 2 3 4 5 8 6 7 11 ...
Страница 36: ...3 III 1 2 ...
Страница 37: ...4 III 1 2 3 4 A B ...
Страница 38: ...5 III C A 1 A 2 A 3 A 4 A 5 ...
Страница 39: ...6 III A 6 A 7 A 8 A 9 B 1 B 2 ...
Страница 40: ...7 III B 3 B 4 B 5 B 6 B 7 C 1 ...
Страница 41: ...8 III C 2 C 3 C 4 ...
Страница 42: ...9 IV D 1 D 2 D 3 D 4 D 5 D 6 ...
Страница 43: ...10 IV D 7 D 8 D 9 D 10 D 11 D 12 ...
Страница 44: ...11 IV D 13 D 14 D 15 D 16 D 17 D 18 ...
Страница 45: ...12 IV D 19 D 20 D 21 D 22 D 23 D 24 ...
Страница 46: ...13 IV D 25 ...