When the DDC and plant configuration stages are finished, the user settings
must still be
defined before switching on the plant - i.e. all the plant operating parameters according to the
operating mode chosen during the plant configuration stage. At this point, the Plant Control menu
may be used to switch the plant/plants configured on and off.
4.5.2
DDC CONFIGURATION INSTRUCTIONS
To carry out the configuration of the DDC or DDCs, proceed as indicated in Paragraph 4.5.2.1 or Paragraph
4.5.2.2, according to whether the plant is managed by a single DDC or by multiple DDCs.
4.5.2.1 Single DDC configuration
In this stage the DDC identifies the units in order to be able to assign them to the DDC itself.
Before carrying out this step, ensure that:
All the units that the DDC must manage are powered and on;
The configuration of the electronic board of each unit has been carried out according to the instructions
provided in the S61 installation manual;
The DDC has been correctly connected, following the instructions contained in Paragraph 4.1.2 –
“
CONNECTING THE DIRECT DIGITAL CONTROLLER
”.
To complete this initial configuration stage, follow the instructions provided in the following paragraphs:
1 -
“Machine configuration” - 4.4.1.4
;
2 -
“Checking machine configuration” - 4.4.1.5
(optional); verify the outcome of the configuration just
carried out.
When this configuration stage is complete, proceed directly to paragraph
4.5.3
- “
PLANT CONFIGURATION
INSTRUCTIONS
”, where it is possible to define the operating mode of the plant.
4.5.2.2 Multi DDC Binding
In order to configure a Multi DDC plant, it is necessary to carry out
5
operations,
strictly in the order
described,
and following the instructions given in the paragraphs indicated:
1 -
“Setting ID” – 4.4.1.1
each DDC is assigned its own ID (DDC IDs must be assigned so that they are all
different from each other);
2 -
“Machine configuration” - 4.4.1.4
; each existing DDC is assigned the units that it is to control. For AFY
60-119/4 units, it is possible to assign just one module to a DDC, e.g. the cold module, having the
remaining module managed by a different DDC;
3 -
“Checking machine configuration” - 4.4.1.5
(optional); verify the outcome of the configuration just
carried out;
4 -
“Master DDC Setup (Multi DDC plants only)” - 4.4.1.6:
; here, the role of each DDC (Master or Slave)
is defined. For a given plant, only one DDC may be configured as the Master DDC, and the others must
be configured as Slaves
If a DDC manages 2 plants (hot and cold), carry out step 4 for both plants.
5 -
“Multi DDC configuration” – 4.4.1.7
during the execution of this operation, which must be carried out
simultaneously on all the DDCs of the plant, and after the first 4 operations on all of them have been
carried out, the DDCs exchange information about the machines assigned to them, to determine whether
they must be co-ordinated with each other to manage certain units. This occurs when units, or modules of
units, have been assigned to more than one DDC, linked to the same plant.
WARNING
NOTE