Normal operation
Installation, use and maintenance manual – Calorio M
25
6
flashing hand icon
to indicate that manual opera-
tion is only temporary.
6.5
ACCESS TO THE USER MENU
To access the user information/settings menu (USER),
press the B MENU
button for more than 5 seconds: the
screens (submenus) will be displayed in sequence starting
from the first (TIME - time/minute/day setting) to the last
(BLOC - keypad lock) (see Table 6.2
p. 25).
To move between the submenus, turn the knob to select
the desired submenu and confirm by pressing the knob.
Table 6.2
User menu
Function
Display
Time and day setting
12:00
Day setting
1)
Comfort temperature setting
COMF
Economy temperature setting
ECON
Antifreeze temperature setting
nOFr
Time schedule programming
PrOG
Limiting heat output
PLim (NOT ACTIVE)
Display backlight setting
TMBL
Temperature level display type
°C
Keypad lock function
BLOC
6.5.1
Setting the time and the day of yhe week
1. Press button B MENU
for 5 seconds and use the
knob (press - turn - press) to set the desired hours and
minutes.
2. Select the day of the week using the knob: 1 =
Monday…7 = Sunday.
The default setting is 12:00 for the time and 1
(Monday) for the day.
6.5.2
Setting the comfort/economy temperature
(for automatic operation)
1. Press for 5 seconds button B MENU
and turn the
knob until the display shows COMF and the sun icon
; using the knob (press - turn - press), set the de-
sired comfort temperature (the default setting is level
4.0 or 20 °C). The comfort temperature is the tempera-
ture that the gas-fired convector will maintain during
the on periods of automatic operation.
The comfort temperature must be higher than the
economy temperature.
2. Press button B MENU
and turn the knob until the
display shows ECON and the moon icon
; using the
knob (press - turn - press), set the desired economy
temperature (the default setting is level 2.0 or 10 °C).
The economy temperature is the temperature that
the gas-fired convector will maintain during the off
periods of automatic operation.
If the economy temperature is set to off, the
heating will be switched off (any antifreeze will not
work either, even if it is enabled).
6.5.3
Antifreeze temperature setting
1. Press for 5 seconds button B MENU
and turn the
knob until the display shows "nOFr" (antifreeze) using
the knob (press - turn - press), set the desired anti-
freeze temperature (the default setting is level 1.0 or
5 °C).
The antifreeze temperature can be set from off to
level 2.0 (10 °C).
To disable the antifreeze function set the value to
off.
6.5.4
Heating/ventilation hourly time schedule
1. Press button B MENU
for 5 seconds and turn the
knob until the display shows "PrOG".
2. Using the knob, select the day (1 = Monday, …, 7 =
Sunday) or blocks of days (1-5 from Monday to Friday;
6 and 7 Saturday and Sunday; 1-7 every day) for which
you want to program automatic operation.
3. Confirm the selection by pressing the knob.
4. Using the knob, select the point ON or OFF for which
you want to set the start time (ON1; ON2, ON3) or stop
time (OF1; OF2, OF3) for heating/ventilation.
5. Confirm the selection by pressing the knob.
6. By turning and pressing the knob, set the ON and OFF
times for the heating/ventilation.
7. Confirmation by pressing the knob stores the time and
moves on to the next ON/OFF point.
It is possible to set up to 3 on/off points.
6.5.5
Power/ventilation limiting function
The power/ventilation limiting function, for this version of
Calorio M, is not active.
6.5.6
Display backlight function
1. Press button B MENU
for 5 seconds and turn the
knob until the display shows "TMBL" (backlight timer).
2. Using the knob (press - rotate - press) you can set:
▶
OFF: backlight always off
▶
5...240: duration in seconds of backlighting since last
button press or knob rotation
▶
ON: backlight always on
The default setting is 60 seconds.
6.5.7
Display of temperature levels / °C
The values of the room set temperatures (manual, anti-
freeze, economy and comfort) can be displayed in levels
(1.0 to 6.0) or in °C (5 °C to 30 °C).
The default setting is OFF (temperature displayed