Bit
Item
Description
Bit
1
-
Unused, Always ‘0’
Bit
0
Input Voltage Error
Detect input voltage exceeds the configured operating voltage
NOTE
:
1. If Shutdown occurs, LED will flicker every second. (
Firmware v41 or above
)
2. If Shutdown occurs,
reboot the device
.
H/W REBOOT : Turn off and turn on the power again
S/W REBOOT : Transmit REBOOT Instruction (For more details, refer to the
section of
e-Manual.)
Controls Torque ON/OFF. Writing ‘1’ to this address will turn on the Torque and all Data in the
EEPROM area will be protected.
Value
Description
0(Default) Turn off the torque
1
Turn on the torque and lock EEPROM area
NOTE
:
can be reset when
are
updated. For more details, please refer to the
Turn on or turn off the LED on DYNAMIXEL.
Bit
Description
0(Default) Turn OFF the LED
1
Turn ON the LED
NOTE
: The LED indicates present status of the device.
Status
LED Representation
Booting
LED flickers once
Factory Reset
LED flickers 4 times
Alarm
LED flickers
Boot Mode
LED On